SMA Solar official logoCEC-Listed · 240V ResidentialString

SMA Solar SB3.0-1SP-US-41 (3 kW)

3.0 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
155–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SMA Solar SB3.0-1SP-US-41 — Real SMA Sunny Boy solar inverter
Real SMA Sunny Boy solar inverterWikimedia Commons — File:Dornbirn-SMA Sunny Boy inverter SWR 3000-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 155–480 Vdc 155V 480V MAX 480V PV DC INPUT ≤ 480V DC 3 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

SMA Solar SB3.0-1SP-US-41 Electrical and Grid-Support Specifications
ManufacturerSMA Solar
Model Number (MPN)SB3.0-1SP-US-41
Inverter TopologyString Inverter
Continuous AC Power (Paco)3 kW (3,000 W)
Nominal DC Input (Pdco)3,094 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window155 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current8.5 A
Night Tare Loss5.39 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SB3.0-1SP-US-41
Max Continuous AC Current12.5 A @ 240V
125% Continuous Duty Current15.6 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (3.3–4.05 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SB3.0-1SP-US-41
Panel ClassRecommended QtyDC Array / Ratio
400W8–10 panels3.2–4.0 kW DC
440W8–9 panels3.5–4.0 kW DC
550W6–7 panels3.3–3.9 kW DC

Compatible Solar Panels for SMA Solar SB3.0-1SP-US-41

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SMA Solar SB3.0-1SP-US-41
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — SMA Solar SB3.0-1SP-US-41

What size circuit breaker does the SMA Solar SB3.0-1SP-US-41 require under NEC 705.12?
At 3 kW continuous AC output on 240V (12.5A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SMA Solar SB3.0-1SP-US-41?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3 kW unit with 3.3 kW to 4.05 kW DC of solar modules without exceeding 480V cold Voc.

More SMA Solar Inverters

SBSE9.6-US-50 (9.569 kW)SBSE11.5-US-50 (11.483 kW)SB3.0-1SP-US-40 (3 kW)SB3.8-1SP-US-40 (3.8 kW)SBS3.8-US-10 (3.8 kW)SB3.8-1SP-US-41 (3.84 kW)All SMA Solar Equipment →