Sol-Ark official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Sol-Ark 5K-120V/8K-230V-1P (7.97 kW)

8 kW, 240 Vac Grid Support Utility Interactive PV and Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.97 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–425V / 425V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sol-Ark 5K-120V/8K-230V-1P — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–425 Vdc 200V 425V MAX 425V PV DC INPUT ≤ 425V DC 7.97 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Sol-Ark 5K-120V/8K-230V-1P Electrical and Grid-Support Specifications
ManufacturerSol-Ark
Model Number (MPN)5K-120V/8K-230V-1P
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)7.97 kW (7,970 W)
Nominal DC Input (Pdco)8,339 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants120V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 425 Vdc (NREL SAM Measured)
Max DC Input Voltage425 Vdc
Max DC Input Current26.7 A
Night Tare Loss19.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryTUV Rheinland
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 5K-120V/8K-230V-1P
Max Continuous AC Current33.2 A @ 240V
125% Continuous Duty Current41.5 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.77–10.76 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 5K-120V/8K-230V-1P
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–24 panels8.8–10.6 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for Sol-Ark 5K-120V/8K-230V-1P

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Sol-Ark 5K-120V/8K-230V-1P
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–5 per string (-10°C)Verify Pair

Engineering FAQ — Sol-Ark 5K-120V/8K-230V-1P

What size circuit breaker does the Sol-Ark 5K-120V/8K-230V-1P require under NEC 705.12?
At 7.97 kW continuous AC output on 240V (33.2A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Sol-Ark 5K-120V/8K-230V-1P?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.97 kW unit with 8.77 kW to 10.76 kW DC of solar modules without exceeding 425V cold Voc.

More Sol-Ark Inverters

Limitless 15K-LV (15.04 kW)Limitless 18K-2P-LV (17.944 kW)SA-MP-1000-208/240V (1.009 kW)8k-48-ST (8.818 kW)12K-P (8.982 kW)Limitless 10K-LV (9.97 kW)All Sol-Ark Equipment →