Sol-Ark official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Sol-Ark 12K-P (8.982 kW)

9 kW, 240 Vac Grid Support Utility Interactive PV and Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.982 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
240–425V / 425V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sol-Ark 12K-P — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 240–425 Vdc 240V 425V MAX 425V PV DC INPUT ≤ 425V DC 8.982 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

Sol-Ark 12K-P Electrical and Grid-Support Specifications
ManufacturerSol-Ark
Model Number (MPN)12K-P
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.982 kW (8,982 W)
Nominal DC Input (Pdco)9,253 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window240 – 425 Vdc (NREL SAM Measured)
Max DC Input Voltage425 Vdc
Max DC Input Current25 A
Night Tare Loss13.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 12K-P
Max Continuous AC Current37.4 A @ 240V
125% Continuous Duty Current46.8 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (9.88–12.13 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 12K-P
Panel ClassRecommended QtyDC Array / Ratio
400W25–30 panels10.0–12.0 kW DC
440W22–28 panels9.7–12.3 kW DC
550W18–22 panels9.9–12.1 kW DC

Compatible Solar Panels for Sol-Ark 12K-P

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Sol-Ark 12K-P
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V10–10 per string (-10°C)Verify Pair

Engineering FAQ — Sol-Ark 12K-P

What size circuit breaker does the Sol-Ark 12K-P require under NEC 705.12?
At 8.982 kW continuous AC output on 240V (37.4A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Sol-Ark 12K-P?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.982 kW unit with 9.88 kW to 12.13 kW DC of solar modules without exceeding 425V cold Voc.

More Sol-Ark Inverters

SA-MP-1000-208/240V (1.009 kW)5K-120V/8K-230V-1P (7.97 kW)8k-48-ST (8.818 kW)Limitless 10K-LV (9.97 kW)12K-2P-LL (11.963 kW)Limitless 15K-LV (15.04 kW)All Sol-Ark Equipment →