Sol-Ark official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Sol-Ark SA-MP-1000-208/240V (1.009 kW)

1000 W, 240Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.009 kW
CEC Weighted Eff.
96%
MPPT / Max DC
40–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sol-Ark SA-MP-1000-208/240V — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 40–55 Vdc 40V 55V MAX 55V PV DC INPUT ≤ 55V DC 1.009 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Sol-Ark SA-MP-1000-208/240V Electrical and Grid-Support Specifications
ManufacturerSol-Ark
Model Number (MPN)SA-MP-1000-208/240V
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.009 kW (1,009 W)
Nominal DC Input (Pdco)1,052 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96%
MPPT Operating Window40 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current22.1 A
Night Tare Loss2.31 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryTUV Rheinland of North America
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SA-MP-1000-208/240V
Max Continuous AC Current4.2 A @ 240V
125% Continuous Duty Current5.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.11–1.36 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SA-MP-1000-208/240V
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.40× DC/AC)
440W1 panel1:1 pairing (0.44× DC/AC)
550W1 panel1:1 pairing (0.55× DC/AC)

Engineering FAQ — Sol-Ark SA-MP-1000-208/240V

What size circuit breaker does the Sol-Ark SA-MP-1000-208/240V require under NEC 705.12?
At 1.009 kW continuous AC output on 240V (4.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Sol-Ark SA-MP-1000-208/240V?
As a 1009W microinverter, it pairs 1:1 with panels rated roughly 1059W to 1463W STC.

More Sol-Ark Inverters

12K-2P-LL (11.963 kW)Limitless 15K-LV (15.04 kW)Limitless 18K-2P-LV (17.944 kW)5K-120V/8K-230V-1P (7.97 kW)8k-48-ST (8.818 kW)12K-P (8.982 kW)All Sol-Ark Equipment →