SolarEdge official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SolarEdge SE3000H-US (2.962 kW)

3.0 kW, 240 Vac HD-Wave technology hybrid Grid Support Utility Interactive Inverter, with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
2.962 kW
CEC Weighted Eff.
99%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE3000H-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 2.962 kW · 99% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE3000H-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE3000H-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)2.962 kW (2,962 W)
Nominal DC Input (Pdco)2,987 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency99%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current15 A
Night Tare LossNot reported in CEC
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE3000H-US
Max Continuous AC Current12.3 A @ 240V
125% Continuous Duty Current15.4 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (3.26–4 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE3000H-US
Panel ClassRecommended QtyDC Array / Ratio
400W8–10 panels3.2–4.0 kW DC
440W7–9 panels3.1–4.0 kW DC
550W6–7 panels3.3–3.9 kW DC

Engineering FAQ — SolarEdge SE3000H-US

What size circuit breaker does the SolarEdge SE3000H-US require under NEC 705.12?
At 2.962 kW continuous AC output on 240V (12.3A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SolarEdge SE3000H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 2.962 kW unit with 3.26 kW to 4 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

SE11400H-US (11.393 kW)NX11500T-US (11.52 kW)NX13000T-US (13 kW)SE3000x (3.01 kW)SE3300x (3.251 kW)SE3800H-US (3.747 kW)All SolarEdge Equipment →