SolarEdge official logoCEC-Listed · 240V ResidentialString

SolarEdge SE3000x (3.01 kW)

3 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter, where x = (blank), A, or A-US. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.01 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
100–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE3000x — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 100–480 Vdc 100V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.01 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE3000x Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE3000x
Inverter TopologyString Inverter
Continuous AC Power (Paco)3.01 kW (3,010 W)
Nominal DC Input (Pdco)3,085 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency97.5%
MPPT Operating Window100 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current15 A
Night Tare Loss3.39 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE3000x
Max Continuous AC Current12.5 A @ 240V
125% Continuous Duty Current15.6 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (3.31–4.06 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE3000x
Panel ClassRecommended QtyDC Array / Ratio
400W8–10 panels3.2–4.0 kW DC
440W8–9 panels3.5–4.0 kW DC
550W6–7 panels3.3–3.9 kW DC

Compatible Solar Panels for SolarEdge SE3000x

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for SolarEdge SE3000x
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V3–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V3–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V3–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V3–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V3–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–6 per string (-10°C)Verify Pair

Engineering FAQ — SolarEdge SE3000x

What size circuit breaker does the SolarEdge SE3000x require under NEC 705.12?
At 3.01 kW continuous AC output on 240V (12.5A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the SolarEdge SE3000x?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.01 kW unit with 3.31 kW to 4.06 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters