SolarEdge official logoCEC-Listed · 240V ResidentialString

SolarEdge SE6000x (5.99 kW)

6 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter, where x = (blank), A, or A-US. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.99 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
370–500V / 500V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE6000x — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 370–500 Vdc 370V 500V MAX 500V PV DC INPUT ≤ 500V DC 5.99 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE6000x Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE6000x
Inverter TopologyString Inverter
Continuous AC Power (Paco)5.99 kW (5,990 W)
Nominal DC Input (Pdco)6,177 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97.5%
MPPT Operating Window370 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage500 Vdc
Max DC Input Current14.2 A
Night Tare Loss3.52 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE6000x
Max Continuous AC Current25 A @ 240V
125% Continuous Duty Current31.3 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.59–8.09 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE6000x
Panel ClassRecommended QtyDC Array / Ratio
400W16–20 panels6.4–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

Engineering FAQ — SolarEdge SE6000x

What size circuit breaker does the SolarEdge SE6000x require under NEC 705.12?
At 5.99 kW continuous AC output on 240V (25A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarEdge SE6000x?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.99 kW unit with 6.59 kW to 8.09 kW DC of solar modules without exceeding 500V cold Voc.

More SolarEdge Inverters