SolarEdge official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SolarEdge SE5700H-US (5.7 kW)

5.7 kW, 240 Vac, 1-phase, Grid Support Utility Interactive Inverter, with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.7 kW
CEC Weighted Eff.
99%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE5700H-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.7 kW · 99% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 30A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE5700H-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE5700H-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.7 kW (5,700 W)
Nominal DC Input (Pdco)5,762 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency99%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current14.6 A
Night Tare Loss4.51 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE5700H-US
Max Continuous AC Current23.8 A @ 240V
125% Continuous Duty Current29.8 A
Minimum Standard Breaker30 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.27–7.7 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE5700H-US
Panel ClassRecommended QtyDC Array / Ratio
400W16–19 panels6.4–7.6 kW DC
440W14–18 panels6.2–7.9 kW DC
550W11–14 panels6.0–7.7 kW DC

Engineering FAQ — SolarEdge SE5700H-US

What size circuit breaker does the SolarEdge SE5700H-US require under NEC 705.12?
At 5.7 kW continuous AC output on 240V (23.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the SolarEdge SE5700H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.7 kW unit with 6.27 kW to 7.7 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

NX5000T-US (4.99 kW)SE5000x (4.99 kW)SE5000H-US (5.052 kW)NX5700T-US (5.76 kW)SE6000x (5.99 kW)NX6000T-US (6 kW)All SolarEdge Equipment →