CEC-Listed · Commercial / C&ICommercial 3-PhaseUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet
Solis (Ginlong) S6-EH3P100K10-NV-YD-H-US (99.945 kW)
100 kW, 480 Vac Grid Support Utility Interactive Hybrid Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
99.945 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
250–850V / 1000VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
175A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Solis (Ginlong) |
|---|---|
| Model Number (MPN) | S6-EH3P100K10-NV-YD-H-US |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 99.945 kW (99,945 W) |
| Nominal DC Input (Pdco) | 102,508 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 250 – 850 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design |
| Max DC Input Voltage | 1000 Vdc |
| Max DC Input Current | 191.6 A |
| Night Tare Loss | 40.78 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 120.2 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 150.3 A |
| Minimum Standard Breaker | 175 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (109.94–134.93 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 275–337 panels | 110.0–134.8 kW DC |
| 440W | 250–307 panels | 110.0–135.1 kW DC |
| 550W | 200–245 panels | 110.0–134.8 kW DC |
CEC-Listed 240V Equivalents to Solis (Ginlong) S6-EH3P100K10-NV-YD-H-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (99.945 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Solis (Ginlong) S6-EH3P100K10-NV-YD-H-US
Test any of 3,007 panels with this inverter →Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (250–850 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–17 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–18 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–14 per string (-10°C) | Verify Pair |
Engineering FAQ — Solis (Ginlong) S6-EH3P100K10-NV-YD-H-US
What size circuit breaker does the Solis (Ginlong) S6-EH3P100K10-NV-YD-H-US require under NEC 705.12?
At 99.945 kW continuous AC output on 480V (120.2A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Solis (Ginlong) S6-EH3P100K10-NV-YD-H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 99.945 kW unit with 109.94 kW to 134.93 kW DC of solar modules without exceeding 1000V cold Voc.