SL Global / Non-US ReferenceHybridBattery Hybrid

Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid) (10 kW)

10 kW, 400V 50Hz Hybrid Inverter (IEC 62109 / EN 50549 (EU/Global)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .

Continuous AC Output
10 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
200–850V / 1000V
NEC 705.12 Breaker
20A @ 400V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid) — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–850 Vdc 200V 850V MAX 1000V PV DC INPUT ≤ 1000V DC 10 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 400V · 20A BRKR

Electrical & Grid-Support Datasheet

Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid) Electrical and Grid-Support Specifications
ManufacturerSolis (Ginlong)
Model Number (MPN)S6-EH3P10K-H-EU (3-Phase Hybrid)
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)10 kW (10,000 W)
Nominal DC Input (Pdco)10,256 W
Nominal AC Voltage400 Vac (3-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window200 – 850 Vdc (Manufacturer IEC Datasheet)
Max DC Input Voltage1000 Vdc
Max DC Input Current16 A
Night Tare Loss2 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SANo
Certifying LaboratoryIEC 62109 / EN 50549 (EU/Global)
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for S6-EH3P10K-H-EU (3-Phase Hybrid)
Max Continuous AC Current14.4 A @ 400V
125% Continuous Duty Current18.0 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (11–13.5 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for S6-EH3P10K-H-EU (3-Phase Hybrid)
Panel ClassRecommended QtyDC Array / Ratio
400W28–34 panels11.2–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

CEC-Listed 240V Equivalents to Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid)

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (10 kW Hybrid Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V10 kW
SolarEdge · Hybrid

NX10000T-US

CEC Efficiency: 99%
Datasheet →
CEC-Listed · 240V10 kW
Univix Power Solutions · Hybrid

UVX10KLNA

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V10.001 kW
Fortress Power · Hybrid

Avalon HV PC100

CEC Efficiency: 97%
Datasheet →

Compatible Solar Panels for Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid)

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid)
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–17 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–17 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–17 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–18 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–18 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–14 per string (-10°C)Verify Pair

Engineering FAQ — Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid)

What size circuit breaker does the Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid) require under NEC 705.12?
At 10 kW continuous AC output on 400V (14.4A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Solis (Ginlong) S6-EH3P10K-H-EU (3-Phase Hybrid)?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10 kW unit with 11 kW to 13.5 kW DC of solar modules without exceeding 1000V cold Voc.

More Solis (Ginlong) Inverters

S6-EH2P14K03-SV-YD-L-US (13.96 kW)S6-EH2P16K03-SV-YD-L-US (15.911 kW)S6-EH2P16K03-SV-YD-L-US-E (15.94 kW)1P2.5K-4G-US (2.5 kW)1P3K-4G-US (3 kW)1P3.6K-4G-US (3.6 kW)All Solis (Ginlong) Equipment →