Solis (Ginlong) 40K-US-LSW (39.926 kW)
40 kW, 480 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
39.926 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
556–800V / 800V
NEC 705.12 Breaker
60A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Solis (Ginlong) |
|---|---|
| Model Number (MPN) | 40K-US-LSW |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 39.926 kW (39,926 W) |
| Nominal DC Input (Pdco) | 40,601 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 556 – 800 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 58 A |
| Night Tare Loss | 1 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 48 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 60.0 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (43.92–53.9 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 110–135 panels | 44.0–54.0 kW DC |
| 440W | 100–123 panels | 44.0–54.1 kW DC |
| 550W | 80–98 panels | 44.0–53.9 kW DC |
CEC-Listed 240V Equivalents to Solis (Ginlong) 40K-US-LSW
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (39.926 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Solis (Ginlong) 40K-US-LSW
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 21–21 per string (-10°C) | Verify Pair |
Engineering FAQ — Solis (Ginlong) 40K-US-LSW
What size circuit breaker does the Solis (Ginlong) 40K-US-LSW require under NEC 705.12?
At 39.926 kW continuous AC output on 480V (48A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Solis (Ginlong) 40K-US-LSW?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 39.926 kW unit with 43.92 kW to 53.9 kW DC of solar modules without exceeding 800V cold Voc.