Sungrow SG350HX-US (320.865 kW)
350 kW, 800 Vac, 3-phase, Transformerless Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
320.865 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
860–1330V / 1330V
NEC 705.12 Breaker
300A @ 800V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Sungrow |
|---|---|
| Model Number (MPN) | SG350HX-US |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 320.865 kW (320,865 W) |
| Nominal DC Input (Pdco) | 326,477 W |
| Nominal AC Voltage | 800 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 860 – 1330 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1330 Vdc |
| Max DC Input Current | 276.7 A |
| Night Tare Loss | 4.83 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 231.6 A @ 800V |
|---|---|
| 125% Continuous Duty Current | 289.5 A |
| Minimum Standard Breaker | 300 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (352.95–433.17 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 882–1083 panels | 352.8–433.2 kW DC |
| 440W | 802–984 panels | 352.9–433.0 kW DC |
| 550W | 642–788 panels | 353.1–433.4 kW DC |
CEC-Listed 240V Equivalents to Sungrow SG350HX-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (320.865 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Sungrow SG350HX-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 23–23 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 23–23 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 24–24 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 24–24 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 33–33 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445 | 445 W | 40.16 V | 30–30 per string (-10°C) | Verify Pair |
Engineering FAQ — Sungrow SG350HX-US
What size circuit breaker does the Sungrow SG350HX-US require under NEC 705.12?
At 320.865 kW continuous AC output on 800V (231.6A continuous), the 125% continuous duty rule requires a minimum 300A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Sungrow SG350HX-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 320.865 kW unit with 352.95 kW to 433.17 kW DC of solar modules without exceeding 1330V cold Voc.