Sungrow SC1000KU (1001.306 kW)
1000 kW, 540 Vac Grid Support Utility Interactive Storage Inverter, bi-directional for use with battery management system, intended to be used in conjunction with a 1000 KVA (min) rated isolation transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
1001.306 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
810–1200V / 1200V
NEC 705.12 Breaker
1400A @ 540V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Sungrow |
|---|---|
| Model Number (MPN) | SC1000KU |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 1001.306 kW (1,001,306 W) |
| Nominal DC Input (Pdco) | 1,038,430 W |
| Nominal AC Voltage | 540 Vac (3-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 810 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 1033.3 A |
| Night Tare Loss | 83.76 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1070.6 A @ 540V |
|---|---|
| 125% Continuous Duty Current | 1338.3 A |
| Minimum Standard Breaker | 1400 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (1101.44–1351.76 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 2754–3379 panels | 1101.6–1351.6 kW DC |
| 440W | 2503–3072 panels | 1101.3–1351.7 kW DC |
| 550W | 2003–2458 panels | 1101.7–1351.9 kW DC |
CEC-Listed 240V Equivalents to Sungrow SC1000KU
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1001.306 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Sungrow SC1000KU
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-450-BTD-BG | 450 W | 39.6 V | 28–28 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 31–31 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540QM | 540 W | 47.96 V | 23–23 per string (-10°C) | Verify Pair |
| REC Solar REC415AA Pure-P | 415 W | 49.1 V | 22–22 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM-R | 435 W | 40.7 V | 27–27 per string (-10°C) | Verify Pair |
Engineering FAQ — Sungrow SC1000KU
What size circuit breaker does the Sungrow SC1000KU require under NEC 705.12?
At 1001.306 kW continuous AC output on 540V (1070.6A continuous), the 125% continuous duty rule requires a minimum 1400A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Sungrow SC1000KU?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1001.306 kW unit with 1101.44 kW to 1351.76 kW DC of solar modules without exceeding 1200V cold Voc.