SG CEC-Listed · Commercial / C&ICommercial 3-PhaseUL 1741-SB (3rd Ed.)Battery Hybrid

Sungrow SG4400UD-MV-US (1103 kW)

4400 kW, 645 Vac Hybrid Grid Support Utility Interactive Inverter connects to the grid via a 4400 kVA medium voltage transformer. (Made up of four SG1100UD-US installed together, each rated max output power = 1103). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1103 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
915–1449V / 1449V
NEC 705.12 Breaker
1300A @ 645V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Sungrow SG4400UD-MV-US — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 915–1449 Vdc 915V 1449V MAX 1449V PV DC INPUT ≤ 1449V DC 1103 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 645V · 1300A BRKR

Electrical & Grid-Support Datasheet

Sungrow SG4400UD-MV-US Electrical and Grid-Support Specifications
ManufacturerSungrow
Model Number (MPN)SG4400UD-MV-US
Inverter TopologyCommercial 3-Phase Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)1103 kW (1,103,000 W)
Nominal DC Input (Pdco)1,135,700 W
Nominal AC Voltage645 Vac (3-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window915 – 1449 Vdc (NREL SAM Measured)
Max DC Input Voltage1449 Vdc
Max DC Input Current1032.5 A
Night Tare Loss128.74 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SG4400UD-MV-US
Max Continuous AC Current987.3 A @ 645V
125% Continuous Duty Current1234.1 A
Minimum Standard Breaker1300 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1213.3–1489.05 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SG4400UD-MV-US
Panel ClassRecommended QtyDC Array / Ratio
400W3033–3723 panels1213.2–1489.2 kW DC
440W2758–3384 panels1213.5–1489.0 kW DC
550W2206–2707 panels1213.3–1488.8 kW DC

CEC-Listed 240V Equivalents to Sungrow SG4400UD-MV-US

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1103 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Compatible Solar Panels for Sungrow SG4400UD-MV-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Sungrow SG4400UD-MV-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V24–25 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V25–25 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V26–26 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V26–26 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V20–20 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V35–36 per string (-10°C)Verify Pair

Engineering FAQ — Sungrow SG4400UD-MV-US

What size circuit breaker does the Sungrow SG4400UD-MV-US require under NEC 705.12?
At 1103 kW continuous AC output on 645V (987.3A continuous), the 125% continuous duty rule requires a minimum 1300A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Sungrow SG4400UD-MV-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1103 kW unit with 1213.3 kW to 1489.05 kW DC of solar modules without exceeding 1449V cold Voc.

More Sungrow Inverters

SC450HX-US (452.492 kW)SC1000KU (1001.306 kW)SG3150UD-MV-US (1053 kW)SC1200UD-US (1203.052 kW)SC1375UD-US (1378.936 kW)SC1575UD-US (1582.996 kW)All Sungrow Equipment →