Sungrow SG4400UD-MV-US (1103 kW)
4400 kW, 645 Vac Hybrid Grid Support Utility Interactive Inverter connects to the grid via a 4400 kVA medium voltage transformer. (Made up of four SG1100UD-US installed together, each rated max output power = 1103). Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
1103 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
915–1449V / 1449V
NEC 705.12 Breaker
1300A @ 645V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Sungrow |
|---|---|
| Model Number (MPN) | SG4400UD-MV-US |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 1103 kW (1,103,000 W) |
| Nominal DC Input (Pdco) | 1,135,700 W |
| Nominal AC Voltage | 645 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 915 – 1449 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1449 Vdc |
| Max DC Input Current | 1032.5 A |
| Night Tare Loss | 128.74 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 987.3 A @ 645V |
|---|---|
| 125% Continuous Duty Current | 1234.1 A |
| Minimum Standard Breaker | 1300 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (1213.3–1489.05 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 3033–3723 panels | 1213.2–1489.2 kW DC |
| 440W | 2758–3384 panels | 1213.5–1489.0 kW DC |
| 550W | 2206–2707 panels | 1213.3–1488.8 kW DC |
CEC-Listed 240V Equivalents to Sungrow SG4400UD-MV-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1103 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Sungrow SG4400UD-MV-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 24–25 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 25–25 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 26–26 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 26–26 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 20–20 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 35–36 per string (-10°C) | Verify Pair |
Engineering FAQ — Sungrow SG4400UD-MV-US
What size circuit breaker does the Sungrow SG4400UD-MV-US require under NEC 705.12?
At 1103 kW continuous AC output on 645V (987.3A continuous), the 125% continuous duty rule requires a minimum 1300A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Sungrow SG4400UD-MV-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1103 kW unit with 1213.3 kW to 1489.05 kW DC of solar modules without exceeding 1449V cold Voc.