Tesla Energy official logoCEC-Listed · 240V ResidentialStringUL 1741-SB (3rd Ed.)

Tesla Energy 1538000-xx-y (7.575 kW)

7.68 kW, 240 Vac Grid Support Utility Interactive Inverter, where xx is two numbers and y is a letter. This inverter can be a component of the Energy Storage System 1850000-XX-Y. Inverter is capable of PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.575 kW
CEC Weighted Eff.
98%
MPPT / Max DC
270–480V / 480V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Tesla Energy 1538000-xx-y — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 270–480 Vdc 270V 480V MAX 480V PV DC INPUT ≤ 480V DC 7.575 kW · 98% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Tesla Energy 1538000-xx-y Electrical and Grid-Support Specifications
ManufacturerTesla Energy
Model Number (MPN)1538000-xx-y
Inverter TopologyString Inverter
Continuous AC Power (Paco)7.575 kW (7,575 W)
Nominal DC Input (Pdco)7,766 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency98%
MPPT Operating Window270 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current20.7 A
Night Tare Loss6.91 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 1538000-xx-y
Max Continuous AC Current31.6 A @ 240V
125% Continuous Duty Current39.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.33–10.23 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 1538000-xx-y
Panel ClassRecommended QtyDC Array / Ratio
400W21–26 panels8.4–10.4 kW DC
440W19–23 panels8.4–10.1 kW DC
550W15–19 panels8.3–10.4 kW DC

Compatible Solar Panels for Tesla Energy 1538000-xx-y

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Tesla Energy 1538000-xx-y
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Tesla Energy 1538000-xx-y

What size circuit breaker does the Tesla Energy 1538000-xx-y require under NEC 705.12?
At 7.575 kW continuous AC output on 240V (31.6A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Tesla Energy 1538000-xx-y?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.575 kW unit with 8.33 kW to 10.23 kW DC of solar modules without exceeding 480V cold Voc.

More Tesla Energy Inverters

1707000-XX-Y (9.991 kW)1534000-xx-y (3.8 kW)All Tesla Energy Equipment →