Tesla Energy official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Tesla Energy 1707000-XX-Y (9.991 kW)

10 kW, 240 Vac Grid Support Utility Interactive Powerwall 3 Integrated Energy Storage System Inverter, where XX are numbers and Y is a letter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.991 kW
CEC Weighted Eff.
96.2%
MPPT / Max DC
270–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Tesla Energy 1707000-XX-Y — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 270–480 Vdc 270V 480V MAX 480V PV DC INPUT ≤ 480V DC 9.991 kW · 96.2% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Tesla Energy 1707000-XX-Y Electrical and Grid-Support Specifications
ManufacturerTesla Energy
Model Number (MPN)1707000-XX-Y
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.991 kW (9,991 W)
Nominal DC Input (Pdco)11,841 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.2%
MPPT Operating Window270 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current31.6 A
Night Tare Loss0.11 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 1707000-XX-Y
Max Continuous AC Current41.6 A @ 240V
125% Continuous Duty Current52.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.99–13.49 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 1707000-XX-Y
Panel ClassRecommended QtyDC Array / Ratio
400W27–34 panels10.8–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Tesla Energy 1707000-XX-Y

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Tesla Energy 1707000-XX-Y
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Tesla Energy 1707000-XX-Y

What size circuit breaker does the Tesla Energy 1707000-XX-Y require under NEC 705.12?
At 9.991 kW continuous AC output on 240V (41.6A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Tesla Energy 1707000-XX-Y?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.991 kW unit with 10.99 kW to 13.49 kW DC of solar modules without exceeding 480V cold Voc.

More Tesla Energy Inverters

1534000-xx-y (3.8 kW)1538000-xx-y (7.575 kW)All Tesla Energy Equipment →