Univix Power Solutions UVX5KLNA (5 kW)
5.0 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
5 kW
CEC Weighted Eff.
97%
MPPT / Max DC
180–430V / 430V
NEC 705.12 Breaker
30A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Univix Power Solutions |
|---|---|
| Model Number (MPN) | UVX5KLNA |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 5 kW (5,000 W) |
| Nominal DC Input (Pdco) | 5,154 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 180 – 430 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 430 Vdc |
| Max DC Input Current | 14.3 A |
| Night Tare Loss | 22.6 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 20.8 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 26.0 A |
| Minimum Standard Breaker | 30 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (5.5–6.75 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 14–17 panels | 5.6–6.8 kW DC |
| 440W | 13–15 panels | 5.7–6.6 kW DC |
| 550W | 10–12 panels | 5.5–6.6 kW DC |
Compatible Solar Panels for Univix Power Solutions UVX5KLNA
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 5–7 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 5–7 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 5–7 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 5–7 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 5–7 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 4–6 per string (-10°C) | Verify Pair |
Engineering FAQ — Univix Power Solutions UVX5KLNA
What size circuit breaker does the Univix Power Solutions UVX5KLNA require under NEC 705.12?
At 5 kW continuous AC output on 240V (20.8A continuous), the 125% continuous duty rule requires a minimum 30A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Univix Power Solutions UVX5KLNA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5 kW unit with 5.5 kW to 6.75 kW DC of solar modules without exceeding 430V cold Voc.