Victron Energy Quattro 48/10000/140-100/100 (8 kW)
8 kW, 230V 50Hz Hybrid Inverter (EN-IEC 60335 (Dual-AC Off-Grid/ESS)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
Continuous AC Output
8 kW
CEC Weighted Eff.
96%
MPPT / Max DC
38–66V / 66V
NEC 705.12 Breaker
45A @ 230V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Victron Energy |
|---|---|
| Model Number (MPN) | Quattro 48/10000/140-100/100 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 8 kW (8,000 W) |
| Nominal DC Input (Pdco) | 8,333 W |
| Nominal AC Voltage | 230 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 96% |
| MPPT Operating Window | 38 – 66 Vdc (Manufacturer IEC Datasheet) |
| Max DC Input Voltage | 66 Vdc |
| Max DC Input Current | 200 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | EN-IEC 60335 (Dual-AC Off-Grid/ESS) |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 34.8 A @ 230V |
|---|---|
| 125% Continuous Duty Current | 43.5 A |
| Minimum Standard Breaker | 45 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (8.8–10.8 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 22–27 panels | 8.8–10.8 kW DC |
| 440W | 20–25 panels | 8.8–11.0 kW DC |
| 550W | 16–20 panels | 8.8–11.0 kW DC |
CEC-Listed 240V Equivalents to Victron Energy Quattro 48/10000/140-100/100
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (8 kW Hybrid Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V7.999 kW
Afore New Energy Technology (Shanghai) · Hybrid
AF8K-DH
CEC Efficiency: 96.5%
Engineering FAQ — Victron Energy Quattro 48/10000/140-100/100
What size circuit breaker does the Victron Energy Quattro 48/10000/140-100/100 require under NEC 705.12?
At 8 kW continuous AC output on 230V (34.8A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Victron Energy Quattro 48/10000/140-100/100?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8 kW unit with 8.8 kW to 10.8 kW DC of solar modules without exceeding 66V cold Voc.