Victron Energy MultiPlus-II 48/8000/110-100 (6.4 kW)
6.4 kW, 230V 50Hz Hybrid Inverter (EN-IEC 60335 (Off-Grid/ESS)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
Continuous AC Output
6.4 kW
CEC Weighted Eff.
95%
MPPT / Max DC
38–66V / 66V
NEC 705.12 Breaker
35A @ 230V
Inverter Engineering Tools
Global / Non-US Reference: Designed for non-US 50Hz / 230V–400V grids; not UL 1741-SB listed for US interconnection.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Victron Energy |
|---|---|
| Model Number (MPN) | MultiPlus-II 48/8000/110-100 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 6.4 kW (6,400 W) |
| Nominal DC Input (Pdco) | 6,737 W |
| Nominal AC Voltage | 230 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 95% |
| MPPT Operating Window | 38 – 66 Vdc (Manufacturer IEC Datasheet) |
| Max DC Input Voltage | 66 Vdc |
| Max DC Input Current | 160 A |
| Night Tare Loss | 2 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | EN-IEC 60335 (Off-Grid/ESS) |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 27.8 A @ 230V |
|---|---|
| 125% Continuous Duty Current | 34.8 A |
| Minimum Standard Breaker | 35 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (7.04–8.64 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 18–22 panels | 7.2–8.8 kW DC |
| 440W | 16–20 panels | 7.0–8.8 kW DC |
| 550W | 13–16 panels | 7.2–8.8 kW DC |
CEC-Listed 240V Equivalents to Victron Energy MultiPlus-II 48/8000/110-100
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (6.4 kW Hybrid Inverter) and can be added directly to your US System Kit:
Engineering FAQ — Victron Energy MultiPlus-II 48/8000/110-100
What size circuit breaker does the Victron Energy MultiPlus-II 48/8000/110-100 require under NEC 705.12?
At 6.4 kW continuous AC output on 230V (27.8A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Victron Energy MultiPlus-II 48/8000/110-100?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.4 kW unit with 7.04 kW to 8.64 kW DC of solar modules without exceeding 66V cold Voc.