Reference US Solar ConfigurationFlorida (FL)1:1 Retail

10.8 kW Canadian + SolarEdge + Battery Solar Kit (Florida)

DC-Coupled Optimized Roof + Battery · Florida Hurricane Backup. Reference Bill of Materials pairing 25× Canadian Solar CS6.2-48TM-430H with 1× SolarEdge SE9600H-US and 1× SolarEdge Home Battery 400V (BAT-10K1P).

System Size
10.75 kW DC / 9.57 kW AC
Est. Annual Yield
16,833 kWh
Est. Savings (FL)
$2,415/yr
Turnkey Cash Est.
$37,716Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · FL RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (25×) Canadian Solar CS6.2-48… 10.75 kW DC STC DC 2. INVERTER (1×) SolarEdge SE9600H-US 9.57 kW AC · 240V 50A 3. MAIN PANEL & GRID Line-Side Tap Required 50A Backfeed · FL Grid 4. HOME ENERGY STORAGE (1×) SolarEdge Home Battery 400V (BA… · 9.7 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 10.8 kW Canadian + SolarEdge + Battery Solar Kit (Florida)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesCanadian SolarCS6.2-48TM-430H25×10.75 kW DC (519 sq ft)Panel Specs →
InverterSolarEdgeSE9600H-US1×9.57 kW AC · 1.12× DC/AC · 50A BreakerInverter Specs →
Energy StorageSolarEdgeHome Battery 400V (BAT-10K1P)1×9.7 kWh usable capacityBattery Specs →

Cost & Sizing Notes for Florida

Modeled at Florida’s average residential electricity rate (15.1¢/kWh) under 1:1 Retail, this 10.75 kW DC / 9.57 kW AC array produces an estimated 16,833 kWh/year (~$2,415/yr gross bill offset, simple pre-incentive payback ~15.6 years at the $37,716 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 519 sq ft, with a 1.12× DC/AC ratio and a 50A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $37,716 estimate for this 10.75 kW Florida solar kit?
The $37,716 figure is a pre-incentive 2026 turnkey cash estimate covering 25× Canadian Solar CS6.2-48TM-430H panels, 1× SolarEdge SE9600H-US, 1× SolarEdge Home Battery 400V (BAT-10K1P) (9.7 kWh), racking, permitting, and licensed installation in Florida. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 10.75 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 9.57 kW continuous AC output, the inverter requires a 50A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 50A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference Florida Solar Kits

10.4 kW Qcells + Enphase + Battery Solar Kit (Florida)11.0 kW REC + Tesla + Battery Solar Kit (Florida)10.6 kW Silfab + Sol-Ark + Battery Solar Kit (Florida)10.6 kW JinkoSolar + EG4 + Battery Solar Kit (Florida)All 120 Kits →