SolarEdge official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

SolarEdge SE9600H-US (9.568 kW)

9.6 kW, 240 Vac, 1-phase, HD-Wave technology Grid Support Utility Interactive Inverter, with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
9.568 kW
CEC Weighted Eff.
99%
MPPT / Max DC
360–460V / 460V
NEC 705.12 Breaker
50A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE9600H-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 360–460 Vdc 360V 460V MAX 460V PV DC INPUT ≤ 460V DC 9.568 kW · 99% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 50A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE9600H-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE9600H-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)9.568 kW (9,568 W)
Nominal DC Input (Pdco)9,713 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency99%
MPPT Operating Window360 – 460 Vdc (NREL SAM Measured)
Max DC Input Voltage460 Vdc
Max DC Input Current24.6 A
Night Tare Loss6 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE9600H-US
Max Continuous AC Current39.9 A @ 240V
125% Continuous Duty Current49.9 A
Minimum Standard Breaker50 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (10.52–12.92 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE9600H-US
Panel ClassRecommended QtyDC Array / Ratio
400W26–32 panels10.4–12.8 kW DC
440W24–29 panels10.6–12.8 kW DC
550W19–23 panels10.4–12.7 kW DC

Engineering FAQ — SolarEdge SE9600H-US

What size circuit breaker does the SolarEdge SE9600H-US require under NEC 705.12?
At 9.568 kW continuous AC output on 240V (39.9A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge SE9600H-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 9.568 kW unit with 10.52 kW to 12.92 kW DC of solar modules without exceeding 460V cold Voc.