Reference US Solar ConfigurationCalifornia (CA)Export Rate (NEM 3.0)

16.2 kW Qcells + Enphase + Battery Solar Kit (California)

Microinverter Roof-Shade Standard · Large Home EV + Heat Pump. Reference Bill of Materials pairing 39× Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 with 39× Enphase Energy IQ8M-72-2-US and 2× Enphase Energy IQ Battery 5P (IQBATTERY-5P-1P-NA).

System Size
16.18 kW DC / 12.68 kW AC
Est. Annual Yield
26,717 kWh
Est. Savings (CA)
$7,476/yr
Turnkey Cash Est.
$59,931Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (39×) Qcells (Hanwha) Q.TRON… 16.18 kW DC STC DC 2. INVERTER (39×) Enphase Energy IQ8M-72-2-… 12.68 kW AC · 240V 70A 3. MAIN PANEL & GRID Line-Side Tap Required 70A Backfeed · CA Grid 4. HOME ENERGY STORAGE (2×) Enphase Energy IQ Battery 5P (I… · 10.0 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 16.2 kW Qcells + Enphase + Battery Solar Kit (California)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesQcells (Hanwha)Q.TRON BLK M-G2.D+ 41539×16.18 kW DC (793 sq ft)Panel Specs →
InverterEnphase EnergyIQ8M-72-2-US39×12.68 kW AC · 1.28× DC/AC · 70A BreakerInverter Specs →
Energy StorageEnphase EnergyIQ Battery 5P (IQBATTERY-5P-1P-NA)2×10 kWh usable capacityBattery Specs →

Cost & Sizing Notes for California

Modeled at California’s average residential electricity rate (31.8¢/kWh) under Export Rate (NEM 3.0), this 16.18 kW DC / 12.68 kW AC array produces an estimated 26,717 kWh/year (~$7,476/yr gross bill offset, simple pre-incentive payback ~8.0 years at the $59,931 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 793 sq ft, with a 1.28× DC/AC ratio and a 70A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $59,931 estimate for this 16.18 kW California solar kit?
The $59,931 figure is a pre-incentive 2026 turnkey cash estimate covering 39× Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 panels, 39× Enphase Energy IQ8M-72-2-US, 2× Enphase Energy IQ Battery 5P (IQBATTERY-5P-1P-NA) (10 kWh), racking, permitting, and licensed installation in California. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 16.18 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 12.68 kW continuous AC output, the inverter requires a 70A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 70A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference California Solar Kits

6.2 kW Qcells + Enphase + Battery Solar Kit (California)11.0 kW REC + Tesla + Battery Solar Kit (California)13.2 kW REC + Tesla + Battery Solar Kit (California)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (California)All 120 Kits →