Reference US Solar ConfigurationCalifornia (CA)Export Rate (NEM 3.0)

6.2 kW Qcells + Enphase + Battery Solar Kit (California)

Microinverter Roof-Shade Standard · California NEM 3.0 Starter. Reference Bill of Materials pairing 15× Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 with 15× Enphase Energy IQ8M-72-2-US and 1× Enphase Energy IQ Battery 5P (IQBATTERY-5P-1P-NA).

System Size
6.22 kW DC / 4.88 kW AC
Est. Annual Yield
10,271 kWh
Est. Savings (CA)
$2,123/yr
Turnkey Cash Est.
$24,449Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (15×) Qcells (Hanwha) Q.TRON… 6.22 kW DC STC DC 2. INVERTER (15×) Enphase Energy IQ8M-72-2-… 4.88 kW AC · 240V 30A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 30A Backfeed · CA Grid 4. HOME ENERGY STORAGE (1×) Enphase Energy IQ Battery 5P (I… · 5.0 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 6.2 kW Qcells + Enphase + Battery Solar Kit (California)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesQcells (Hanwha)Q.TRON BLK M-G2.D+ 41515×6.22 kW DC (305 sq ft)Panel Specs →
InverterEnphase EnergyIQ8M-72-2-US15×4.88 kW AC · 1.27× DC/AC · 30A BreakerInverter Specs →
Energy StorageEnphase EnergyIQ Battery 5P (IQBATTERY-5P-1P-NA)1×5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for California

Modeled at California’s average residential electricity rate (31.8¢/kWh) under Export Rate (NEM 3.0), this 6.22 kW DC / 4.88 kW AC array produces an estimated 10,271 kWh/year (~$2,123/yr gross bill offset, simple pre-incentive payback ~11.5 years at the $24,449 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 305 sq ft, with a 1.27× DC/AC ratio and a 30A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $24,449 estimate for this 6.22 kW California solar kit?
The $24,449 figure is a pre-incentive 2026 turnkey cash estimate covering 15× Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 panels, 15× Enphase Energy IQ8M-72-2-US, 1× Enphase Energy IQ Battery 5P (IQBATTERY-5P-1P-NA) (5 kWh), racking, permitting, and licensed installation in California. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 6.22 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 4.88 kW continuous AC output, the inverter requires a 30A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 30A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference California Solar Kits

16.2 kW Qcells + Enphase + Battery Solar Kit (California)11.0 kW REC + Tesla + Battery Solar Kit (California)13.2 kW REC + Tesla + Battery Solar Kit (California)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (California)All 120 Kits →