Reference US Solar ConfigurationCalifornia (CA)Export Rate (NEM 3.0)

11.0 kW REC + Tesla + Battery Solar Kit (California)

NEM 3.0 & Whole-Home Integrated Flagship · California NEM 3.0 Starter. Reference Bill of Materials pairing 25× REC Solar REC440AA Pure-RX-DC with 1× Tesla Energy 1707000-XX-Y and 1× Tesla Energy Powerwall 3 (1707000-XX-Y).

System Size
11 kW DC / 9.99 kW AC
Est. Annual Yield
18,164 kWh
Est. Savings (CA)
$5,083/yr
Turnkey Cash Est.
$45,180Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · CA RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (25×) REC Solar REC440AA Pure… 11.00 kW DC STC DC 2. INVERTER (1×) Tesla Energy 1707000-XX-Y 9.99 kW AC · 240V 60A 3. MAIN PANEL & GRID Line-Side Tap Required 60A Backfeed · CA Grid 4. HOME ENERGY STORAGE (1×) Tesla Energy Powerwall 3 (17070… · 13.5 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 11.0 kW REC + Tesla + Battery Solar Kit (California)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesREC SolarREC440AA Pure-RX-DC25×11 kW DC (544 sq ft)Panel Specs →
InverterTesla Energy1707000-XX-Y1×9.99 kW AC · 1.1× DC/AC · 60A BreakerInverter Specs →
Energy StorageTesla EnergyPowerwall 3 (1707000-XX-Y)1×13.5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for California

Modeled at California’s average residential electricity rate (31.8¢/kWh) under Export Rate (NEM 3.0), this 11 kW DC / 9.99 kW AC array produces an estimated 18,164 kWh/year (~$5,083/yr gross bill offset, simple pre-incentive payback ~8.9 years at the $45,180 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 544 sq ft, with a 1.1× DC/AC ratio and a 60A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $45,180 estimate for this 11 kW California solar kit?
The $45,180 figure is a pre-incentive 2026 turnkey cash estimate covering 25× REC Solar REC440AA Pure-RX-DC panels, 1× Tesla Energy 1707000-XX-Y, 1× Tesla Energy Powerwall 3 (1707000-XX-Y) (13.5 kWh), racking, permitting, and licensed installation in California. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 11 kW solar kit fit on a standard 225A electrical panel under NEC 705.12?
At 9.99 kW continuous AC output, the inverter requires a 60A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 60A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference California Solar Kits

6.2 kW Qcells + Enphase + Battery Solar Kit (California)16.2 kW Qcells + Enphase + Battery Solar Kit (California)13.2 kW REC + Tesla + Battery Solar Kit (California)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (California)All 120 Kits →