Reference US Solar ConfigurationNorth Carolina (NC)Avoided Cost

8.4 kW REC + SMA + Battery Solar Kit (North Carolina)

German-Engineered Hybrid + Modular LFP Backup · North Carolina PowerPair. Reference Bill of Materials pairing 19× REC Solar REC440AA Pure-RX-DC with 1× SMA Solar SBSE7.7-US-50 and 1× SMA Solar SMA-ESS-SBS3.8-BYDH7.5.

System Size
8.36 kW DC / 7.62 kW AC
Est. Annual Yield
11,900 kWh
Est. Savings (NC)
$1,106/yr
Turnkey Cash Est.
$31,040Pre-incentive cash estimate
SYSTEM SINGLE-LINE ARCHITECTURE · NC RESIDENTIAL 240V SPLIT-PHASE 1. SOLAR ARRAY (19×) REC Solar REC440AA Pure… 8.36 kW DC STC DC 2. INVERTER (1×) SMA Solar SBSE7.7-US-50 7.62 kW AC · 240V 40A 3. MAIN PANEL & GRID 200A Busbar · NEC 705.12 40A Backfeed · NC Grid 4. HOME ENERGY STORAGE (1×) SMA Solar SMA-ESS-SBS3.8-BYDH7.5 · 7.5 kWh

Reference Bill of Materials & NEC Summary

Bill of Materials for 8.4 kW REC + SMA + Battery Solar Kit (North Carolina)
ItemManufacturerModelQtyElectrical RatingDatasheet
Solar ModulesREC SolarREC440AA Pure-RX-DC19×8.36 kW DC (413 sq ft)Panel Specs →
InverterSMA SolarSBSE7.7-US-501×7.62 kW AC · 1.1× DC/AC · 40A BreakerInverter Specs →
Energy StorageSMA SolarSMA-ESS-SBS3.8-BYDH7.51×7.5 kWh usable capacityBattery Specs →

Cost & Sizing Notes for North Carolina

Modeled at North Carolina’s average residential electricity rate (14.3¢/kWh) under Avoided Cost, this 8.36 kW DC / 7.62 kW AC array produces an estimated 11,900 kWh/year (~$1,106/yr gross bill offset, simple pre-incentive payback ~28.1 years at the $31,040 pre-incentive cash estimate). Required south-facing unshaded roof area is approximately 413 sq ft, with a 1.1× DC/AC ratio and a 40A NEC 705.12 backfeed breaker. Always confirm local structural wind/snow loads and utility interconnection rules before ordering equipment.

What is included in the $31,040 estimate for this 8.36 kW North Carolina solar kit?
The $31,040 figure is a pre-incentive 2026 turnkey cash estimate covering 19× REC Solar REC440AA Pure-RX-DC panels, 1× SMA Solar SBSE7.7-US-50, 1× SMA Solar SMA-ESS-SBS3.8-BYDH7.5 (7.5 kWh), racking, permitting, and licensed installation in North Carolina. It excludes expired federal Section 25D credits and any state or utility rebates you may qualify for.
Will this 8.36 kW solar kit fit on a standard 200A electrical panel under NEC 705.12?
At 7.62 kW continuous AC output, the inverter requires a 40A backfeed breaker (125% continuous duty). Under the NEC 705.12(B) 120% busbar rule, a standard 200A/200A panel allows up to a 40A solar breaker; if 40A exceeds 40A, a 225A busbar, main-breaker derate (175A), or supply-side tap is required.

More Reference North Carolina Solar Kits

8.3 kW Qcells + Enphase + Battery Solar Kit (North Carolina)11.0 kW REC + Tesla + Battery Solar Kit (North Carolina)8.8 kW Silfab + Sol-Ark + Battery Solar Kit (North Carolina)8.8 kW JinkoSolar + EG4 + Battery Solar Kit (North Carolina)All 120 Kits →