AMPS Solar AMPS-550P-144SW
550 W, 144 half-cut cell double-glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
550W / 518.4W
Efficiency
21.48%
Voc / Vmp
49.05V / 41.55V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | AMPS Solar |
|---|---|
| Model Number (MPN) | AMPS-550P-144SW |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 550 W |
| Real-World Output (PTC) | 518.4 W (94.3% of STC) |
| Module Efficiency | 21.48% (214.8 W/m²) |
| Open-Circuit Voltage (Voc) | 49.05 V |
| Maximum Power Voltage (Vmp) | 41.55 V |
| Short-Circuit Current (Isc) | 14.18 A (NEC 1.25× = 17.73 A) |
| Maximum Power Current (Imp) | 13.25 A |
| Temp. Coeff. Power (γPmax) | -0.335 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.253 %/°C |
| Temp. Coeff. Current (αIsc) | +0.046 %/°C |
| Nominal Cell Temp (NOCT) | 43.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.56 m² (27.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.253%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.05 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.15 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.39 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.63 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 55.88 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.05 kW | 303 sq ft (28.2 m²) |
| 8 kW | 15 panels | 8.25 kW | 413 sq ft (38.4 m²) |
| 10 kW | 19 panels | 10.45 kW | 524 sq ft (48.6 m²) |
| 12 kW | 22 panels | 12.10 kW | 606 sq ft (56.3 m²) |
Compatible CEC-Listed Inverters for AMPS-550P-144SW
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.43 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This AMPS Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| AMPS-525P-144SW | 525 W | 494.3 W | 48.43 V | 13.87 A | 20.51% |
| AMPS-530P-144SW | 530 W | 499.1 W | 48.55 V | 13.94 A | 20.7% |
| AMPS-535P-144SW | 535 W | 503.9 W | 48.67 V | 14.01 A | 20.9% |
| AMPS-540P-144SW | 540 W | 508.7 W | 48.81 V | 14.06 A | 21.09% |
| AMPS-545P-144SW | 545 W | 513.6 W | 48.91 V | 14.12 A | 21.29% |
Engineering FAQ — AMPS Solar AMPS-550P-144SW
How many AMPS Solar AMPS-550P-144SW panels can fit in one 600V string?
At -10°C (14°F) ambient, the AMPS-550P-144SW open-circuit voltage rises from 49.05V to 53.39V (using βVoc -0.253%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the AMPS Solar AMPS-550P-144SW?
Rated at 550W STC, the AMPS-550P-144SW carries a 518.4W PTC rating (94.3% PTC/STC ratio) and 21.48% module efficiency across 2.56 m² (27.6 sq ft).
Is the AMPS Solar AMPS-550P-144SW listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.