AMPS Solar AMPS-600N-144SW
600 W, 144 half-cut cell double-glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
600W / 569.8W
Efficiency
23.44%
Voc / Vmp
53.3V / 44.45V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | AMPS Solar |
|---|---|
| Model Number (MPN) | AMPS-600N-144SW |
| Cell Technology | Mono-c-Si (Bifacial) · 144 cells |
| Nameplate Power (Pmax STC) | 600 W |
| Real-World Output (PTC) | 569.8 W (95% of STC) |
| Module Efficiency | 23.44% (234.4 W/m²) |
| Open-Circuit Voltage (Voc) | 53.3 V |
| Maximum Power Voltage (Vmp) | 44.45 V |
| Short-Circuit Current (Isc) | 14.19 A (NEC 1.25× = 17.74 A) |
| Maximum Power Current (Imp) | 13.5 A |
| Temp. Coeff. Power (γPmax) | -0.305 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.231 %/°C |
| Temp. Coeff. Current (αIsc) | +0.047 %/°C |
| Nominal Cell Temp (NOCT) | 43.3 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.56 m² (27.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.231%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.3 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 56.38 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 57.61 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 58.84 V | 10 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 60.07 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 10 panels | 6.00 kW | 276 sq ft (25.6 m²) |
| 8 kW | 14 panels | 8.40 kW | 386 sq ft (35.8 m²) |
| 10 kW | 17 panels | 10.20 kW | 468 sq ft (43.5 m²) |
| 12 kW | 20 panels | 12.00 kW | 551 sq ft (51.2 m²) |
Compatible CEC-Listed Inverters for AMPS-600N-144SW
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8P-72-2-US | Microinverter | 0.475 kW | 97.5% | 1:1 micro pairing (1.26 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This AMPS Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| AMPS-575N-144SW | 575 W | 545.5 W | 52.3 V | 13.89 A | 22.46% |
| AMPS-580N-144SW | 580 W | 550.3 W | 52.5 V | 13.95 A | 22.66% |
| AMPS-585N-144SW | 585 W | 555.2 W | 52.7 V | 14.01 A | 22.85% |
| AMPS-590N-144SW | 590 W | 560 W | 52.9 V | 14.07 A | 23.05% |
| AMPS-595N-144SW | 595 W | 564.9 W | 53.1 V | 14.13 A | 23.24% |
Engineering FAQ — AMPS Solar AMPS-600N-144SW
How many AMPS Solar AMPS-600N-144SW panels can fit in one 600V string?
At -10°C (14°F) ambient, the AMPS-600N-144SW open-circuit voltage rises from 53.3V to 57.61V (using βVoc -0.231%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the AMPS Solar AMPS-600N-144SW?
Rated at 600W STC, the AMPS-600N-144SW carries a 569.8W PTC rating (95% PTC/STC ratio) and 23.44% module efficiency across 2.56 m² (27.6 sq ft).
Is the AMPS Solar AMPS-600N-144SW listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.