Chint New Energy Technology CHSM66N(DG)/F-BH-685
685 W, 132 half-cut cell bifacial double glass monodrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
685W / 649W
Efficiency
22.03%
Voc / Vmp
47.77V / 39.65V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Chint New Energy Technology |
|---|---|
| Model Number (MPN) | CHSM66N(DG)/F-BH-685 |
| Cell Technology | Mono-c-Si (Bifacial) · 132 cells |
| Nameplate Power (Pmax STC) | 685 W |
| Real-World Output (PTC) | 649 W (94.7% of STC) |
| Module Efficiency | 22.03% (220.3 W/m²) |
| Open-Circuit Voltage (Voc) | 47.77 V |
| Maximum Power Voltage (Vmp) | 39.65 V |
| Short-Circuit Current (Isc) | 18.23 A (NEC 1.25× = 22.79 A) |
| Maximum Power Current (Imp) | 17.28 A |
| Temp. Coeff. Power (γPmax) | -0.304 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.269 %/°C |
| Temp. Coeff. Current (αIsc) | +0.043 %/°C |
| Nominal Cell Temp (NOCT) | 43.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 3.11 m² (33.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.269%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 47.77 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 50.98 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 52.27 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53.55 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.84 V | 10 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 9 panels | 6.17 kW | 301 sq ft (28.0 m²) |
| 8 kW | 12 panels | 8.22 kW | 402 sq ft (37.3 m²) |
| 10 kW | 15 panels | 10.28 kW | 502 sq ft (46.6 m²) |
| 12 kW | 18 panels | 12.33 kW | 603 sq ft (56.0 m²) |
Compatible CEC-Listed Inverters for CHSM66N(DG)/F-BH-685
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8P-72-2-US | Microinverter | 0.475 kW | 97.5% | 1:1 micro pairing (1.44 DC/AC ratio) | Verify Pair |
| Fronius Symo 10.0-3 208-240 | String | 9.995 kW | 96.5% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Chint New Energy Technology Series (17 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| CHSM66N(DG)/F-BH-655 | 655 W | 619 W | 46.56 V | 17.54 A | 21.06% |
| CHSM66N(DG)/F-BH-660 | 660 W | 623.9 W | 46.76 V | 17.62 A | 21.22% |
| CHSM66N(DG)/F-BH-665 | 665 W | 628.7 W | 46.96 V | 17.7 A | 21.38% |
| CHSM66N(DG)/F-BH-670 | 670 W | 633.5 W | 47.17 V | 17.78 A | 21.54% |
| CHSM66N(DG)/F-BH-675 | 675 W | 638.4 W | 47.37 V | 17.86 A | 21.7% |
| CHSM66N(DG)/F-BH-680 | 680 W | 643.2 W | 47.57 V | 17.94 A | 21.86% |
| CHSM66N(DG)/F-BH-690 | 690 W | 653.9 W | 47.97 V | 18.28 A | 22.19% |
| CHSM66N(DG)/F-BH-695 | 695 W | 658.7 W | 48.17 V | 18.33 A | 22.35% |
| CHSM66N(DG)/F-BH-700 | 700 W | 663.6 W | 48.37 V | 18.38 A | 22.51% |
| CHSM66N(DG)/F-BH-705 | 705 W | 668.4 W | 48.57 V | 18.43 A | 22.67% |
| CHSM66N(DG)/F-BH-710 | 710 W | 673.3 W | 48.77 V | 18.48 A | 22.83% |
| CHSM66N(DG)/F-BH-715 | 715 W | 678.1 W | 48.97 V | 18.53 A | 22.99% |
| CHSM66N(DG)/F-BH-720 | 720 W | 683 W | 49.17 V | 18.58 A | 23.15% |
| CHSM66N(DG)/F-BH-725 | 725 W | 687.8 W | 49.37 V | 18.63 A | 23.31% |
Engineering FAQ — Chint New Energy Technology CHSM66N(DG)/F-BH-685
How many Chint New Energy Technology CHSM66N(DG)/F-BH-685 panels can fit in one 600V string?
At -10°C (14°F) ambient, the CHSM66N(DG)/F-BH-685 open-circuit voltage rises from 47.77V to 52.27V (using βVoc -0.269%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Chint New Energy Technology CHSM66N(DG)/F-BH-685?
Rated at 685W STC, the CHSM66N(DG)/F-BH-685 carries a 649W PTC rating (94.7% PTC/STC ratio) and 22.03% module efficiency across 3.11 m² (33.5 sq ft).
Is the Chint New Energy Technology CHSM66N(DG)/F-BH-685 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.