CS CEC-Listed · ResidentialUL 61730

Crossroads Solar 380

380 W, 72 cell monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
380W / 350.5W
Efficiency
18.63%
Voc / Vmp
49V / 40.64V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Crossroads Solar Crossroads Solar 380 — Illustrative category photo — not this exact model · Real monocrystalline rooftop solar array
Illustrative category photo — not this exact model · Real monocrystalline rooftop solar arrayWikimedia Commons — File:Polycrystalline solar panel mj1.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (72 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 53.77V Isc 9.9A MPP 380W (40.64V · 9.35A) Voc 49V DC Voltage (V) · Efficiency 18.63%

Electrical & Thermal Specifications (STC)

Crossroads Solar Crossroads Solar 380 Electrical and Mechanical Specifications
ManufacturerCrossroads Solar
Model Number (MPN)Crossroads Solar 380
Cell TechnologyMono-c-Si · 72 cells
Nameplate Power (Pmax STC)380 W
Real-World Output (PTC)350.5 W (92.2% of STC)
Module Efficiency18.63% (186.3 W/m²)
Open-Circuit Voltage (Voc)49 V
Maximum Power Voltage (Vmp)40.64 V
Short-Circuit Current (Isc)9.9 A (NEC 1.25× = 12.38 A)
Maximum Power Current (Imp)9.35 A
Temp. Coeff. Power (γPmax)-0.378 %/°C
Temp. Coeff. Voltage (βVoc)-0.278 %/°C
Temp. Coeff. Current (αIsc)+0.049 %/°C
Nominal Cell Temp (NOCT)45.8 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area2.04 m² (22.0 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.278%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for Crossroads Solar 380
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
49 V1220
0°C / 32°F
Freezing / Mild Winter
52.41 V1119
-10°C / 14°F
TX / Southeast / Mid-Atlantic
53.77 V1118
-20°C / -4°F
Northeast / Midwest Winter
55.13 V1018
-30°C / -22°F
Northern Plains / Mountain
56.49 V1017

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using Crossroads Solar 380
Target SizePanels NeededActual DCRoof Footprint
6 kW16 panels6.08 kW351 sq ft (32.6 m²)
8 kW22 panels8.36 kW483 sq ft (44.9 m²)
10 kW27 panels10.26 kW593 sq ft (55.1 m²)
12 kW32 panels12.16 kW703 sq ft (65.3 m²)

Compatible CEC-Listed Inverters for Crossroads Solar 380

Open full string calculator with this panel →
Compatible US-Certified Inverters for Crossroads Solar Crossroads Solar 380
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–11 panels/string at -10°CVerify Pair
Enphase Energy IQ6PLUS-ACB-LLMicroinverter0.27 kW95.5%1:1 micro pairing (1.41 DC/AC ratio)Verify Pair
Fronius Primo 3.8-1 208-240String3.8 kW95.5%3–14 panels/string at -10°CVerify Pair
GoodWe GEP5.0-1-US30String4.968 kW96.5%5–9 panels/string at -10°CVerify Pair
Growatt SPH 4000TL BL-USHybrid3.988 kW95%6–8 panels/string at -10°CVerify Pair
Growatt SPH 4600TL BL-USHybrid4.598 kW95%6–8 panels/string at -10°CVerify Pair

Engineering FAQ — Crossroads Solar 380

How many Crossroads Solar 380 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Crossroads Solar 380 open-circuit voltage rises from 49V to 53.77V (using βVoc -0.278%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Crossroads Solar 380?
Rated at 380W STC, the Crossroads Solar 380 carries a 350.5W PTC rating (92.2% PTC/STC ratio) and 18.63% module efficiency across 2.04 m² (22.0 sq ft).
Is the Crossroads Solar 380 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.