Crossroads Solar 380
380 W, 72 cell monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
380W / 350.5W
Efficiency
18.63%
Voc / Vmp
49V / 40.64V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Crossroads Solar |
|---|---|
| Model Number (MPN) | Crossroads Solar 380 |
| Cell Technology | Mono-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 380 W |
| Real-World Output (PTC) | 350.5 W (92.2% of STC) |
| Module Efficiency | 18.63% (186.3 W/m²) |
| Open-Circuit Voltage (Voc) | 49 V |
| Maximum Power Voltage (Vmp) | 40.64 V |
| Short-Circuit Current (Isc) | 9.9 A (NEC 1.25× = 12.38 A) |
| Maximum Power Current (Imp) | 9.35 A |
| Temp. Coeff. Power (γPmax) | -0.378 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.278 %/°C |
| Temp. Coeff. Current (αIsc) | +0.049 %/°C |
| Nominal Cell Temp (NOCT) | 45.8 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.04 m² (22.0 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.278%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.41 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.77 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.13 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.49 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.08 kW | 351 sq ft (32.6 m²) |
| 8 kW | 22 panels | 8.36 kW | 483 sq ft (44.9 m²) |
| 10 kW | 27 panels | 10.26 kW | 593 sq ft (55.1 m²) |
| 12 kW | 32 panels | 12.16 kW | 703 sq ft (65.3 m²) |
Compatible CEC-Listed Inverters for Crossroads Solar 380
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| Growatt SPH 4000TL BL-US | Hybrid | 3.988 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
| Growatt SPH 4600TL BL-US | Hybrid | 4.598 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
Engineering FAQ — Crossroads Solar 380
How many Crossroads Solar 380 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Crossroads Solar 380 open-circuit voltage rises from 49V to 53.77V (using βVoc -0.278%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Crossroads Solar 380?
Rated at 380W STC, the Crossroads Solar 380 carries a 350.5W PTC rating (92.2% PTC/STC ratio) and 18.63% module efficiency across 2.04 m² (22.0 sq ft).
Is the Crossroads Solar 380 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.