EGing PV New Energy (Changzhou) EGPV66D50-690/TP
690 W, 132 half cut cell double glass monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
690W / 653.8W
Efficiency
23.08%
Voc / Vmp
47.9V / 40V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | EGing PV New Energy (Changzhou) |
|---|---|
| Model Number (MPN) | EGPV66D50-690/TP |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 690 W |
| Real-World Output (PTC) | 653.8 W (94.8% of STC) |
| Module Efficiency | 23.08% (230.8 W/m²) |
| Open-Circuit Voltage (Voc) | 47.9 V |
| Maximum Power Voltage (Vmp) | 40 V |
| Short-Circuit Current (Isc) | 18.28 A (NEC 1.25× = 22.85 A) |
| Maximum Power Current (Imp) | 17.25 A |
| Temp. Coeff. Power (γPmax) | -0.294 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.237 %/°C |
| Temp. Coeff. Current (αIsc) | +0.045 %/°C |
| Nominal Cell Temp (NOCT) | 44.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.99 m² (32.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.237%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 47.9 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 50.74 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 51.87 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53.01 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.14 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 9 panels | 6.21 kW | 290 sq ft (26.9 m²) |
| 8 kW | 12 panels | 8.28 kW | 386 sq ft (35.9 m²) |
| 10 kW | 15 panels | 10.35 kW | 483 sq ft (44.9 m²) |
| 12 kW | 18 panels | 12.42 kW | 579 sq ft (53.8 m²) |
Compatible CEC-Listed Inverters for EGPV66D50-690/TP
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8P-72-2-US | Microinverter | 0.475 kW | 97.5% | 1:1 micro pairing (1.45 DC/AC ratio) | Verify Pair |
| Fronius Symo 10.0-3 208-240 | String | 9.995 kW | 96.5% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 4–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This EGing PV New Energy (Changzhou) Series (7 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| EGPV66D50-695/TP | 695 W | 658.6 W | 48.2 V | 18.31 A | 23.24% |
| EGPV66D50-700/TP | 700 W | 663.5 W | 48.5 V | 18.34 A | 23.41% |
| EGPV66D50-705/TP | 705 W | 668.3 W | 48.8 V | 18.37 A | 23.58% |
| EGPV66D50-710/TP | 710 W | 673.2 W | 49.1 V | 18.4 A | 23.75% |
| EGPV66D50-715/TP | 715 W | 678 W | 49.4 V | 18.45 A | 23.91% |
| EGPV66D50-720/TP | 720 W | 682.9 W | 49.7 V | 18.51 A | 24.08% |
Engineering FAQ — EGing PV New Energy (Changzhou) EGPV66D50-690/TP
How many EGing PV New Energy (Changzhou) EGPV66D50-690/TP panels can fit in one 600V string?
At -10°C (14°F) ambient, the EGPV66D50-690/TP open-circuit voltage rises from 47.9V to 51.87V (using βVoc -0.237%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the EGing PV New Energy (Changzhou) EGPV66D50-690/TP?
Rated at 690W STC, the EGPV66D50-690/TP carries a 653.8W PTC rating (94.8% PTC/STC ratio) and 23.08% module efficiency across 2.99 m² (32.2 sq ft).
Is the EGing PV New Energy (Changzhou) EGPV66D50-690/TP listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.