GE Energy GEPVp-205-M
205 W Polycrystalline Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
205W / 177.6W
Efficiency
14.07%
Voc / Vmp
33V / 27.2V
Max String (600V)
16 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | GE Energy |
|---|---|
| Model Number (MPN) | GEPVp-205-M |
| Cell Technology | Multi-c-Si · 54 cells |
| Nameplate Power (Pmax STC) | 205 W |
| Real-World Output (PTC) | 177.6 W (86.6% of STC) |
| Module Efficiency | 14.07% (140.7 W/m²) |
| Open-Circuit Voltage (Voc) | 33 V |
| Maximum Power Voltage (Vmp) | 27.2 V |
| Short-Circuit Current (Isc) | 8.2 A (NEC 1.25× = 10.25 A) |
| Maximum Power Current (Imp) | 7.6 A |
| Temp. Coeff. Power (γPmax) | -0.492 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.371 %/°C |
| Temp. Coeff. Current (αIsc) | +0.074 %/°C |
| Nominal Cell Temp (NOCT) | 50.5 °C |
| Dimensions (L × W) | 1485 × 981 mm (58.5" × 38.6") |
| Surface Area | 1.457 m² (15.7 sq ft) |
| Safety Listing | UL 1703 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.371%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 33 V | 18 | 30 |
| 0°C / 32°F Freezing / Mild Winter | 36.06 V | 16 | 27 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 37.29 V | 16 | 26 |
| -20°C / -4°F Northeast / Midwest Winter | 38.51 V | 15 | 25 |
| -30°C / -22°F Northern Plains / Mountain | 39.73 V | 15 | 25 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 30 panels | 6.15 kW | 470 sq ft (43.7 m²) |
| 8 kW | 40 panels | 8.20 kW | 627 sq ft (58.3 m²) |
| 10 kW | 49 panels | 10.04 kW | 768 sq ft (71.4 m²) |
| 12 kW | 59 panels | 12.10 kW | 925 sq ft (86.0 m²) |
CEC-Listed US Equivalents to GE Energy GEPVp-205-M
Looking to build a compliant US residential system with comparable wattage (205W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for GEPVp-205-M
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–16 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-72-2-US | Microinverter | 0.19 kW | 96.5% | 1:1 micro pairing (1.08 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 5–21 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 8–13 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 8–13 panels/string at -10°C | Verify Pair |
Other Power Classes in This GE Energy Series (2 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GEPVp-200-M | 200 W | 173.1 W | 32.6 V | 8.25 A | 13.73% |
Engineering FAQ — GE Energy GEPVp-205-M
How many GE Energy GEPVp-205-M panels can fit in one 600V string?
At -10°C (14°F) ambient, the GEPVp-205-M open-circuit voltage rises from 33V to 37.29V (using βVoc -0.371%/°C), allowing up to 16 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the GE Energy GEPVp-205-M?
Rated at 205W STC, the GEPVp-205-M carries a 177.6W PTC rating (86.6% PTC/STC ratio) and 14.07% module efficiency across 1.457 m² (15.7 sq ft).
Is the GE Energy GEPVp-205-M listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1703). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.