GU CEC-Listed · ResidentialUL 61730

GermanSolar USA GSM10-Agri-310W-CG

310 W, 84 cell monocrystalline module, 1500 max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
310W / 294.3W
Efficiency
21.99%
Voc / Vmp
30.58V / 26.42V
Max String (600V)
18 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
GermanSolar USA GSM10-Agri-310W-CG — Illustrative category photo — not this exact model · Real monocrystalline rooftop solar array
Illustrative category photo — not this exact model · Real monocrystalline rooftop solar arrayWikimedia Commons — File:Polycrystalline solar panel mj1.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (84 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 33.02V Isc 12.53A MPP 310W (26.42V · 11.73A) Voc 30.58V DC Voltage (V) · Efficiency 21.99%

Electrical & Thermal Specifications (STC)

GermanSolar USA GSM10-Agri-310W-CG Electrical and Mechanical Specifications
ManufacturerGermanSolar USA
Model Number (MPN)GSM10-Agri-310W-CG
Cell TechnologyMono-c-Si · 84 cells
Nameplate Power (Pmax STC)310 W
Real-World Output (PTC)294.3 W (94.9% of STC)
Module Efficiency21.99% (219.9 W/m²)
Open-Circuit Voltage (Voc)30.58 V
Maximum Power Voltage (Vmp)26.42 V
Short-Circuit Current (Isc)12.53 A (NEC 1.25× = 15.66 A)
Maximum Power Current (Imp)11.73 A
Temp. Coeff. Power (γPmax)-0.296 %/°C
Temp. Coeff. Voltage (βVoc)-0.228 %/°C
Temp. Coeff. Current (αIsc)+0.044 %/°C
Nominal Cell Temp (NOCT)43.4 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area1.41 m² (15.2 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.228%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for GSM10-Agri-310W-CG
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
30.58 V1932
0°C / 32°F
Freezing / Mild Winter
32.32 V1830
-10°C / 14°F
TX / Southeast / Mid-Atlantic
33.02 V1830
-20°C / -4°F
Northeast / Midwest Winter
33.72 V1729
-30°C / -22°F
Northern Plains / Mountain
34.41 V1729

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using GSM10-Agri-310W-CG
Target SizePanels NeededActual DCRoof Footprint
6 kW20 panels6.20 kW304 sq ft (28.2 m²)
8 kW26 panels8.06 kW395 sq ft (36.7 m²)
10 kW33 panels10.23 kW501 sq ft (46.5 m²)
12 kW39 panels12.09 kW592 sq ft (55.0 m²)

CEC-Listed US Equivalents to GermanSolar USA GSM10-Agri-310W-CG

Looking to build a compliant US residential system with comparable wattage (310W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:

CEC-Listed · Residential320 W
REC Solar · UL 61730

REC320TP2M

Efficiency: 19.79%
Datasheet →
CEC-Listed · Residential320 W
Solar4America Technology · UL 61730

OPAL320-60MH5

Efficiency: 19.75%
Datasheet →
CEC-Listed · Residential325 W
GermanSolar USA · UL 61730

GSM10-Agri-325W-AG

Efficiency: 22.11%
Datasheet →

Compatible CEC-Listed Inverters for GSM10-Agri-310W-CG

Open full string calculator with this panel →
Compatible US-Certified Inverters for GermanSolar USA GSM10-Agri-310W-CG
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%3–18 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%10–14 panels/string at -10°CVerify Pair
Enphase Energy IQ7PD-84-2-USMicroinverter0.21 kW96.5%1:1 micro pairing (1.48 DC/AC ratio)Verify Pair
Fronius Primo 3.8-1 208-240String3.8 kW95.5%5–24 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%5–14 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%5–14 panels/string at -10°CVerify Pair

Other Power Classes in This GermanSolar USA Series (15 total CEC variants)

Sibling Power Classes in the GermanSolar USA Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
GSM10-Agri-205W-CG205 W194.6 W20.38 V12.44 A21.81%
GSM10-Agri-210W-CG210 W199.4 W20.41 V12.72 A22.34%
GSM10-Agri-215W-CG215 W204.3 W20.44 V13 A22.87%
GSM10-Agri-220W-CG220 W209.1 W20.47 V13.28 A23.4%
GSM10-Agri-225W-CG225 W214 W20.5 V13.56 A23.94%
GSM10-Agri-265W-CG265 W251.5 W26.21 V12.5 A21.9%
GSM10-Agri-270W-CG270 W256.4 W26.24 V12.71 A22.31%
GSM10-Agri-275W-CG275 W261.3 W26.28 V12.93 A22.73%
GSM10-Agri-280W-CG280 W266.1 W26.32 V13.14 A23.14%
GSM10-Agri-285W-CG285 W271 W26.35 V13.35 A23.55%
GSM10-Agri-315W-CG315 W299.1 W30.62 V12.71 A22.34%
GSM10-Agri-320W-CG320 W304 W30.66 V12.89 A22.7%
GSM10-Agri-325W-CG325 W308.9 W30.7 V13.07 A23.05%
GSM10-Agri-330W-CG330 W313.7 W30.74 V13.25 A23.4%

Engineering FAQ — GermanSolar USA GSM10-Agri-310W-CG

How many GermanSolar USA GSM10-Agri-310W-CG panels can fit in one 600V string?
At -10°C (14°F) ambient, the GSM10-Agri-310W-CG open-circuit voltage rises from 30.58V to 33.02V (using βVoc -0.228%/°C), allowing up to 18 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the GermanSolar USA GSM10-Agri-310W-CG?
Rated at 310W STC, the GSM10-Agri-310W-CG carries a 294.3W PTC rating (94.9% PTC/STC ratio) and 21.99% module efficiency across 1.41 m² (15.2 sq ft).
Is the GermanSolar USA GSM10-Agri-310W-CG listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Residential (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.

More GermanSolar USA Solar Panels

GSM10-Agri-400W-AG (400W)GSM10-Agri-330W-CG (330W)GSM10-Agri-325W-AG (325W)GSM-670W-H (670W)GSM-555W-HC (555W)GSM-525W-HC (525W)All GermanSolar USA Equipment →