GermanSolar USA GSM10-Agri-330W-CG
330 W, 84 cell monocrystalline module, 1500 max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
330W / 313.7W
Efficiency
23.4%
Voc / Vmp
30.74V / 26.59V
Max String (600V)
18 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | GermanSolar USA |
|---|---|
| Model Number (MPN) | GSM10-Agri-330W-CG |
| Cell Technology | Mono-c-Si · 84 cells |
| Nameplate Power (Pmax STC) | 330 W |
| Real-World Output (PTC) | 313.7 W (95.1% of STC) |
| Module Efficiency | 23.4% (234 W/m²) |
| Open-Circuit Voltage (Voc) | 30.74 V |
| Maximum Power Voltage (Vmp) | 26.59 V |
| Short-Circuit Current (Isc) | 13.25 A (NEC 1.25× = 16.56 A) |
| Maximum Power Current (Imp) | 12.41 A |
| Temp. Coeff. Power (γPmax) | -0.296 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.228 %/°C |
| Temp. Coeff. Current (αIsc) | +0.044 %/°C |
| Nominal Cell Temp (NOCT) | 43.4 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.41 m² (15.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.228%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 30.74 V | 19 | 32 |
| 0°C / 32°F Freezing / Mild Winter | 32.49 V | 18 | 30 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 33.19 V | 18 | 30 |
| -20°C / -4°F Northeast / Midwest Winter | 33.89 V | 17 | 29 |
| -30°C / -22°F Northern Plains / Mountain | 34.59 V | 17 | 28 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 19 panels | 6.27 kW | 288 sq ft (26.8 m²) |
| 8 kW | 25 panels | 8.25 kW | 379 sq ft (35.3 m²) |
| 10 kW | 31 panels | 10.23 kW | 470 sq ft (43.7 m²) |
| 12 kW | 37 panels | 12.21 kW | 562 sq ft (52.2 m²) |
Compatible CEC-Listed Inverters for GSM10-Agri-330W-CG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–18 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 10–14 panels/string at -10°C | Verify Pair |
| Enphase Energy S230-60-LL-x | Microinverter | 0.22 kW | 97% | 1:1 micro pairing (1.50 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 5–24 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 5–14 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 5–14 panels/string at -10°C | Verify Pair |
Other Power Classes in This GermanSolar USA Series (15 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GSM10-Agri-205W-CG | 205 W | 194.6 W | 20.38 V | 12.44 A | 21.81% |
| GSM10-Agri-210W-CG | 210 W | 199.4 W | 20.41 V | 12.72 A | 22.34% |
| GSM10-Agri-215W-CG | 215 W | 204.3 W | 20.44 V | 13 A | 22.87% |
| GSM10-Agri-220W-CG | 220 W | 209.1 W | 20.47 V | 13.28 A | 23.4% |
| GSM10-Agri-225W-CG | 225 W | 214 W | 20.5 V | 13.56 A | 23.94% |
| GSM10-Agri-265W-CG | 265 W | 251.5 W | 26.21 V | 12.5 A | 21.9% |
| GSM10-Agri-270W-CG | 270 W | 256.4 W | 26.24 V | 12.71 A | 22.31% |
| GSM10-Agri-275W-CG | 275 W | 261.3 W | 26.28 V | 12.93 A | 22.73% |
| GSM10-Agri-280W-CG | 280 W | 266.1 W | 26.32 V | 13.14 A | 23.14% |
| GSM10-Agri-285W-CG | 285 W | 271 W | 26.35 V | 13.35 A | 23.55% |
| GSM10-Agri-310W-CG | 310 W | 294.3 W | 30.58 V | 12.53 A | 21.99% |
| GSM10-Agri-315W-CG | 315 W | 299.1 W | 30.62 V | 12.71 A | 22.34% |
| GSM10-Agri-320W-CG | 320 W | 304 W | 30.66 V | 12.89 A | 22.7% |
| GSM10-Agri-325W-CG | 325 W | 308.9 W | 30.7 V | 13.07 A | 23.05% |
Engineering FAQ — GermanSolar USA GSM10-Agri-330W-CG
How many GermanSolar USA GSM10-Agri-330W-CG panels can fit in one 600V string?
At -10°C (14°F) ambient, the GSM10-Agri-330W-CG open-circuit voltage rises from 30.74V to 33.19V (using βVoc -0.228%/°C), allowing up to 18 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the GermanSolar USA GSM10-Agri-330W-CG?
Rated at 330W STC, the GSM10-Agri-330W-CG carries a 313.7W PTC rating (95.1% PTC/STC ratio) and 23.4% module efficiency across 1.41 m² (15.2 sq ft).
Is the GermanSolar USA GSM10-Agri-330W-CG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.