Goldi Solar Private GOLDI072F400PRC24B
400 W, 72 cell monocrytalline module, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
400W / 375.6W
Efficiency
21.28%
Voc / Vmp
49.65V / 40.48V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Goldi Solar Private |
|---|---|
| Model Number (MPN) | GOLDI072F400PRC24B |
| Cell Technology | Mono-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 400 W |
| Real-World Output (PTC) | 375.6 W (93.9% of STC) |
| Module Efficiency | 21.28% (212.8 W/m²) |
| Open-Circuit Voltage (Voc) | 49.65 V |
| Maximum Power Voltage (Vmp) | 40.48 V |
| Short-Circuit Current (Isc) | 10.21 A (NEC 1.25× = 12.76 A) |
| Maximum Power Current (Imp) | 9.88 A |
| Temp. Coeff. Power (γPmax) | -0.325 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.239 %/°C |
| Temp. Coeff. Current (αIsc) | +0.028 %/°C |
| Nominal Cell Temp (NOCT) | 44.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.88 m² (20.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.239%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.65 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.62 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.8 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.99 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.18 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.00 kW | 304 sq ft (28.2 m²) |
| 8 kW | 20 panels | 8.00 kW | 405 sq ft (37.6 m²) |
| 10 kW | 25 panels | 10.00 kW | 506 sq ft (47.0 m²) |
| 12 kW | 30 panels | 12.00 kW | 607 sq ft (56.4 m²) |
Compatible CEC-Listed Inverters for GOLDI072F400PRC24B
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| Growatt SPH 4600TL BL-US | Hybrid | 4.598 kW | 95% | 6–8 panels/string at -10°C | Verify Pair |
| Growatt MIN 6000TL-XH-US | Hybrid | 5.918 kW | 97% | 5–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Goldi Solar Private Series (11 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GOLDI072F350PRC24B | 350 W | 324.7 W | 47.3 V | 9.48 A | 18.63% |
| GOLDI072F355PRC24B | 355 W | 329.5 W | 47.5 V | 9.56 A | 18.89% |
| GOLDI072F360PRC24B | 360 W | 334.2 W | 47.7 V | 9.64 A | 19.16% |
| GOLDI072F365PRC24B | 365 W | 339 W | 47.9 V | 9.72 A | 19.43% |
| GOLDI072F370PRC24B | 370 W | 343.7 W | 48.1 V | 9.78 A | 19.69% |
| GOLDI072F375PRC24B | 375 W | 348.5 W | 48.4 V | 9.84 A | 19.96% |
| GOLDI072F380PRC24B | 380 W | 353.3 W | 48.7 V | 9.92 A | 20.22% |
| GOLDI072F385PRC24B | 385 W | 361.1 W | 48.9 V | 9.98 A | 20.48% |
| GOLDI072F390PRC24B | 390 W | 366 W | 49.15 V | 10.07 A | 20.74% |
| GOLDI072F395PRC24B | 395 W | 370.8 W | 49.35 V | 10.15 A | 21.01% |
Engineering FAQ — Goldi Solar Private GOLDI072F400PRC24B
How many Goldi Solar Private GOLDI072F400PRC24B panels can fit in one 600V string?
At -10°C (14°F) ambient, the GOLDI072F400PRC24B open-circuit voltage rises from 49.65V to 53.8V (using βVoc -0.239%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Goldi Solar Private GOLDI072F400PRC24B?
Rated at 400W STC, the GOLDI072F400PRC24B carries a 375.6W PTC rating (93.9% PTC/STC ratio) and 21.28% module efficiency across 1.88 m² (20.2 sq ft).
Is the Goldi Solar Private GOLDI072F400PRC24B listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.