Greenlite Solar Canada GLS-270
270 W Polycrystalline Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
270W / 243.1W
Efficiency
14.03%
Voc / Vmp
44.49V / 36.72V
Max String (600V)
12 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Greenlite Solar Canada |
|---|---|
| Model Number (MPN) | GLS-270 |
| Cell Technology | Multi-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 270 W |
| Real-World Output (PTC) | 243.1 W (90% of STC) |
| Module Efficiency | 14.03% (140.3 W/m²) |
| Open-Circuit Voltage (Voc) | 44.49 V |
| Maximum Power Voltage (Vmp) | 36.72 V |
| Short-Circuit Current (Isc) | 7.95 A (NEC 1.25× = 9.94 A) |
| Maximum Power Current (Imp) | 7.45 A |
| Temp. Coeff. Power (γPmax) | -0.44 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.3 %/°C |
| Temp. Coeff. Current (αIsc) | +0.13 %/°C |
| Nominal Cell Temp (NOCT) | 46.2 °C |
| Dimensions (L × W) | 1960 × 982 mm (77.2" × 38.7") |
| Surface Area | 1.925 m² (20.7 sq ft) |
| Safety Listing | UL 1703 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.3%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 44.49 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 47.83 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 49.16 V | 12 | 20 |
| -20°C / -4°F Northeast / Midwest Winter | 50.5 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 51.83 V | 11 | 19 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 23 panels | 6.21 kW | 477 sq ft (44.3 m²) |
| 8 kW | 30 panels | 8.10 kW | 622 sq ft (57.8 m²) |
| 10 kW | 38 panels | 10.26 kW | 787 sq ft (73.2 m²) |
| 12 kW | 45 panels | 12.15 kW | 932 sq ft (86.6 m²) |
CEC-Listed US Equivalents to Greenlite Solar Canada GLS-270
Looking to build a compliant US residential system with comparable wattage (270W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for GLS-270
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-84-2-US | Microinverter | 0.21 kW | 96.5% | 1:1 micro pairing (1.29 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–16 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Greenlite Solar Canada Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| GLS-200 | 200 W | 180 W | 33.37 V | 7.95 A | 13.71% |
| GLS-220 | 220 W | 197.9 W | 37.08 V | 7.95 A | 13.63% |
Engineering FAQ — Greenlite Solar Canada GLS-270
How many Greenlite Solar Canada GLS-270 panels can fit in one 600V string?
At -10°C (14°F) ambient, the GLS-270 open-circuit voltage rises from 44.49V to 49.16V (using βVoc -0.3%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Greenlite Solar Canada GLS-270?
Rated at 270W STC, the GLS-270 carries a 243.1W PTC rating (90% PTC/STC ratio) and 14.03% module efficiency across 1.925 m² (20.7 sq ft).
Is the Greenlite Solar Canada GLS-270 listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1703). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.