Grenzebach Envelon ON Generate-36-S1 (185W)
185 W, 36 cell, monocrystalline BIPV module, double glass, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
185W / 168.4W
Efficiency
16.37%
Voc / Vmp
24.28V / 20.17V
Max String (600V)
22 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Grenzebach Envelon |
|---|---|
| Model Number (MPN) | ON Generate-36-S1 |
| Cell Technology | Mono-c-Si · 36 cells |
| Nameplate Power (Pmax STC) | 185 W |
| Real-World Output (PTC) | 168.4 W (91% of STC) |
| Module Efficiency | 16.37% (163.7 W/m²) |
| Open-Circuit Voltage (Voc) | 24.28 V |
| Maximum Power Voltage (Vmp) | 20.17 V |
| Short-Circuit Current (Isc) | 9.6 A (NEC 1.25× = 12.00 A) |
| Maximum Power Current (Imp) | 9.17 A |
| Temp. Coeff. Power (γPmax) | -0.358 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.269 %/°C |
| Temp. Coeff. Current (αIsc) | +0.037 %/°C |
| Nominal Cell Temp (NOCT) | 49.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.13 m² (12.2 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.269%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 24.28 V | 24 | 41 |
| 0°C / 32°F Freezing / Mild Winter | 25.91 V | 23 | 38 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 26.57 V | 22 | 37 |
| -20°C / -4°F Northeast / Midwest Winter | 27.22 V | 22 | 36 |
| -30°C / -22°F Northern Plains / Mountain | 27.87 V | 21 | 35 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 33 panels | 6.11 kW | 401 sq ft (37.3 m²) |
| 8 kW | 44 panels | 8.14 kW | 535 sq ft (49.7 m²) |
| 10 kW | 55 panels | 10.18 kW | 669 sq ft (62.1 m²) |
| 12 kW | 65 panels | 12.03 kW | 791 sq ft (73.4 m²) |
CEC-Listed US Equivalents to Grenzebach Envelon ON Generate-36-S1
Looking to build a compliant US residential system with comparable wattage (185W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for ON Generate-36-S1
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–22 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 13–18 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-72-2-US | Microinverter | 0.19 kW | 96.5% | 1:1 micro pairing (0.97 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 6–30 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 10–18 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 10–18 panels/string at -10°C | Verify Pair |
Engineering FAQ — Grenzebach Envelon ON Generate-36-S1
How many Grenzebach Envelon ON Generate-36-S1 panels can fit in one 600V string?
At -10°C (14°F) ambient, the ON Generate-36-S1 open-circuit voltage rises from 24.28V to 26.57V (using βVoc -0.269%/°C), allowing up to 22 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Grenzebach Envelon ON Generate-36-S1?
Rated at 185W STC, the ON Generate-36-S1 carries a 168.4W PTC rating (91% PTC/STC ratio) and 16.37% module efficiency across 1.13 m² (12.2 sq ft).
Is the Grenzebach Envelon ON Generate-36-S1 listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.