HALEE HST-61-E-FP
61 W, 14 cell monocrystalline BIPV module, black backsheet, 600V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
61W / 52.2W
Efficiency
14.88%
Voc / Vmp
9.5V / 7.6V
Max String (600V)
57 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | HALEE |
|---|---|
| Model Number (MPN) | HST-61-E-FP |
| Cell Technology | Mono-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 61 W |
| Real-World Output (PTC) | 52.2 W (85.6% of STC) |
| Module Efficiency | 14.88% (148.8 W/m²) |
| Open-Circuit Voltage (Voc) | 9.5 V |
| Maximum Power Voltage (Vmp) | 7.6 V |
| Short-Circuit Current (Isc) | 8.6 A (NEC 1.25× = 10.75 A) |
| Maximum Power Current (Imp) | 8.1 A |
| Temp. Coeff. Power (γPmax) | -0.387 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.263 %/°C |
| Temp. Coeff. Current (αIsc) | +0.028 %/°C |
| Nominal Cell Temp (NOCT) | 60.5 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 0.41 m² (4.4 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.263%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 9.5 V | 63 | 105 |
| 0°C / 32°F Freezing / Mild Winter | 10.12 V | 59 | 98 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 10.37 V | 57 | 96 |
| -20°C / -4°F Northeast / Midwest Winter | 10.62 V | 56 | 94 |
| -30°C / -22°F Northern Plains / Mountain | 10.87 V | 55 | 91 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 99 panels | 6.04 kW | 437 sq ft (40.6 m²) |
| 8 kW | 132 panels | 8.05 kW | 583 sq ft (54.1 m²) |
| 10 kW | 164 panels | 10.00 kW | 724 sq ft (67.2 m²) |
| 12 kW | 197 panels | 12.02 kW | 869 sq ft (80.8 m²) |
CEC-Listed US Equivalents to HALEE HST-61-E-FP
Looking to build a compliant US residential system with comparable wattage (61W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for HST-61-E-FP
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 4–57 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 14–46 panels/string at -10°C | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 7–77 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 11–48 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 11–48 panels/string at -10°C | Verify Pair |
Engineering FAQ — HALEE HST-61-E-FP
How many HALEE HST-61-E-FP panels can fit in one 600V string?
At -10°C (14°F) ambient, the HST-61-E-FP open-circuit voltage rises from 9.5V to 10.37V (using βVoc -0.263%/°C), allowing up to 57 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the HALEE HST-61-E-FP?
Rated at 61W STC, the HST-61-E-FP carries a 52.2W PTC rating (85.6% PTC/STC ratio) and 14.88% module efficiency across 0.41 m² (4.4 sq ft).
Is the HALEE HST-61-E-FP listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.