HE CEC-Listed · ResidentialUL 61730

Hanersun Energy HN18N-54HT425W

425 W, 108 cell, monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .

STC / PTC Power
425W / 403.2W
Efficiency
22.37%
Voc / Vmp
38.1V / 32.1V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Hanersun Energy HN18N-54HT425W — Illustrative category photo — not this exact model · Real monocrystalline rooftop solar array
Illustrative category photo — not this exact model · Real monocrystalline rooftop solar arrayWikimedia Commons — File:Polycrystalline solar panel mj1.jpg (CC BY-SA 4.0)
MODULE FOOTPRINT (108 CELLS) 1722mm (67.8") 1134mm (44.6") STC I–V CURVE & COLD VOC (−10°C) −10°C 41.22V Isc 14.05A MPP 425W (32.1V · 13.24A) Voc 38.1V DC Voltage (V) · Efficiency 22.37%

Electrical & Thermal Specifications (STC)

Hanersun Energy HN18N-54HT425W Electrical and Mechanical Specifications
ManufacturerHanersun Energy
Model Number (MPN)HN18N-54HT425W
Cell TechnologyMono-c-Si · 108 cells
Nameplate Power (Pmax STC)425 W
Real-World Output (PTC)403.2 W (94.9% of STC)
Module Efficiency22.37% (223.7 W/m²)
Open-Circuit Voltage (Voc)38.1 V
Maximum Power Voltage (Vmp)32.1 V
Short-Circuit Current (Isc)14.05 A (NEC 1.25× = 17.56 A)
Maximum Power Current (Imp)13.24 A
Temp. Coeff. Power (γPmax)-0.307 %/°C
Temp. Coeff. Voltage (βVoc)-0.234 %/°C
Temp. Coeff. Current (αIsc)+0.046 %/°C
Nominal Cell Temp (NOCT)43.1 °C
Dimensions (L × W)1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet)
Surface Area1.9 m² (20.5 sq ft) (Est.)
Safety ListingUL 61730

NEC 690.7 Cold-Weather Voc Limits

Computed using this module’s βVoc (-0.234%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.

NEC 690.7 Cold-Weather String Voltage Limits for HN18N-54HT425W
Design Cold TempCold VocMax / 600VMax / 1000V
25°C / 77°F
STC Lab Standard
38.1 V1526
0°C / 32°F
Freezing / Mild Winter
40.33 V1424
-10°C / 14°F
TX / Southeast / Mid-Atlantic
41.22 V1424
-20°C / -4°F
Northeast / Midwest Winter
42.11 V1423
-30°C / -22°F
Northern Plains / Mountain
43 V1323

Residential Array Roof Sizing

Residential Roof Footprint Estimates Using HN18N-54HT425W
Target SizePanels NeededActual DCRoof Footprint
6 kW15 panels6.38 kW307 sq ft (28.5 m²)
8 kW19 panels8.07 kW389 sq ft (36.1 m²)
10 kW24 panels10.20 kW491 sq ft (45.6 m²)
12 kW29 panels12.32 kW593 sq ft (55.1 m²)

Compatible CEC-Listed Inverters for HN18N-54HT425W

Open full string calculator with this panel →
Compatible US-Certified Inverters for Hanersun Energy HN18N-54HT425W
Inverter ModelTopologyAC OutputCEC Eff.Compatibility Check (−10°C)Action
APsystems ELS-3KHybrid3.685 kW94%2–14 panels/string at -10°CVerify Pair
EG4 Electronics IV-8000-HYB-AWHybrid7.863 kW96.5%8–11 panels/string at -10°CVerify Pair
Enphase Energy IQ6PLUS-72-2-USMicroinverter0.28 kW97%1:1 micro pairing (1.52 DC/AC ratio)Verify Pair
Fronius Primo 5.0-1 208-240String5 kW96.5%4–19 panels/string at -10°CVerify Pair
GoodWe GEC5.0-1U-US20Hybrid4.983 kW96%4–12 panels/string at -10°CVerify Pair
GoodWe GW5000-SBP-US20Hybrid4.983 kW96%4–12 panels/string at -10°CVerify Pair

Other Power Classes in This Hanersun Energy Series (5 total CEC variants)

Sibling Power Classes in the Hanersun Energy Series
Series Variant ModelSTC PowerPTC PowerVocIscEfficiency
HN18N-54HT430W430 W408.1 W38.3 V14.12 A22.63%
HN18N-54HT435W435 W412.9 W38.5 V14.19 A22.89%
HN18N-54HT440W440 W417.8 W38.7 V14.26 A23.16%
HN18N-54HT445W445 W422.6 W38.9 V14.33 A23.42%

Engineering FAQ — Hanersun Energy HN18N-54HT425W

How many Hanersun Energy HN18N-54HT425W panels can fit in one 600V string?
At -10°C (14°F) ambient, the HN18N-54HT425W open-circuit voltage rises from 38.1V to 41.22V (using βVoc -0.234%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hanersun Energy HN18N-54HT425W?
Rated at 425W STC, the HN18N-54HT425W carries a 403.2W PTC rating (94.9% PTC/STC ratio) and 22.37% module efficiency across 1.9 m² (20.5 sq ft).
Is the Hanersun Energy HN18N-54HT425W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.

More Hanersun Energy Solar Panels

HN21RN-48HT455W (455W)HN18N-54HT445W (445W)HN21RN-48HT430W (430W)HN21N-66HT705W (705W)HN21N-66HT700W (700W)HN21N-66HT670W (670W)All Hanersun Energy Equipment →