Hanersun Energy HN18N-54HT445W
445 W, 108 cell, monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
445W / 422.6W
Efficiency
23.42%
Voc / Vmp
38.9V / 32.9V
Max String (600V)
14 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hanersun Energy |
|---|---|
| Model Number (MPN) | HN18N-54HT445W |
| Cell Technology | Mono-c-Si · 108 cells |
| Nameplate Power (Pmax STC) | 445 W |
| Real-World Output (PTC) | 422.6 W (95% of STC) |
| Module Efficiency | 23.42% (234.2 W/m²) |
| Open-Circuit Voltage (Voc) | 38.9 V |
| Maximum Power Voltage (Vmp) | 32.9 V |
| Short-Circuit Current (Isc) | 14.33 A (NEC 1.25× = 17.91 A) |
| Maximum Power Current (Imp) | 13.53 A |
| Temp. Coeff. Power (γPmax) | -0.307 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.234 %/°C |
| Temp. Coeff. Current (αIsc) | +0.046 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.9 m² (20.5 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.234%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 38.9 V | 15 | 25 |
| 0°C / 32°F Freezing / Mild Winter | 41.18 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 42.09 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43 V | 13 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 43.91 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.23 kW | 286 sq ft (26.6 m²) |
| 8 kW | 18 panels | 8.01 kW | 368 sq ft (34.2 m²) |
| 10 kW | 23 panels | 10.23 kW | 470 sq ft (43.7 m²) |
| 12 kW | 27 panels | 12.02 kW | 552 sq ft (51.3 m²) |
Compatible CEC-Listed Inverters for HN18N-54HT445W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.53 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–11 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hanersun Energy Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HN18N-54HT425W | 425 W | 403.2 W | 38.1 V | 14.05 A | 22.37% |
| HN18N-54HT430W | 430 W | 408.1 W | 38.3 V | 14.12 A | 22.63% |
| HN18N-54HT435W | 435 W | 412.9 W | 38.5 V | 14.19 A | 22.89% |
| HN18N-54HT440W | 440 W | 417.8 W | 38.7 V | 14.26 A | 23.16% |
Engineering FAQ — Hanersun Energy HN18N-54HT445W
How many Hanersun Energy HN18N-54HT445W panels can fit in one 600V string?
At -10°C (14°F) ambient, the HN18N-54HT445W open-circuit voltage rises from 38.9V to 42.09V (using βVoc -0.234%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hanersun Energy HN18N-54HT445W?
Rated at 445W STC, the HN18N-54HT445W carries a 422.6W PTC rating (95% PTC/STC ratio) and 23.42% module efficiency across 1.9 m² (20.5 sq ft).
Is the Hanersun Energy HN18N-54HT445W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.