Hanersun Energy HN18N-60HT495W
495 W, 120 cell, monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
495W / 470.1W
Efficiency
23.46%
Voc / Vmp
43.4V / 36.5V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Hanersun Energy |
|---|---|
| Model Number (MPN) | HN18N-60HT495W |
| Cell Technology | Mono-c-Si · 120 cells |
| Nameplate Power (Pmax STC) | 495 W |
| Real-World Output (PTC) | 470.1 W (95% of STC) |
| Module Efficiency | 23.46% (234.6 W/m²) |
| Open-Circuit Voltage (Voc) | 43.4 V |
| Maximum Power Voltage (Vmp) | 36.5 V |
| Short-Circuit Current (Isc) | 14.34 A (NEC 1.25× = 17.93 A) |
| Maximum Power Current (Imp) | 13.57 A |
| Temp. Coeff. Power (γPmax) | -0.307 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.234 %/°C |
| Temp. Coeff. Current (αIsc) | +0.046 %/°C |
| Nominal Cell Temp (NOCT) | 43.1 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.11 m² (22.7 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.234%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 43.4 V | 13 | 23 |
| 0°C / 32°F Freezing / Mild Winter | 45.94 V | 13 | 21 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 46.95 V | 12 | 21 |
| -20°C / -4°F Northeast / Midwest Winter | 47.97 V | 12 | 20 |
| -30°C / -22°F Northern Plains / Mountain | 48.99 V | 12 | 20 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.43 kW | 295 sq ft (27.4 m²) |
| 8 kW | 17 panels | 8.41 kW | 386 sq ft (35.9 m²) |
| 10 kW | 21 panels | 10.39 kW | 477 sq ft (44.3 m²) |
| 12 kW | 25 panels | 12.38 kW | 568 sq ft (52.8 m²) |
Compatible CEC-Listed Inverters for HN18N-60HT495W
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–10 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8MC-72-2-US | Microinverter | 0.32 kW | 97% | 1:1 micro pairing (1.55 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 4–17 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 4–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Hanersun Energy Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| HN18N-60HT475W | 475 W | 450.7 W | 42.6 V | 14.16 A | 22.51% |
| HN18N-60HT480W | 480 W | 455.6 W | 42.8 V | 14.21 A | 22.75% |
| HN18N-60HT485W | 485 W | 460.4 W | 43 V | 14.24 A | 22.99% |
| HN18N-60HT490W | 490 W | 465.3 W | 43.2 V | 14.29 A | 23.22% |
Engineering FAQ — Hanersun Energy HN18N-60HT495W
How many Hanersun Energy HN18N-60HT495W panels can fit in one 600V string?
At -10°C (14°F) ambient, the HN18N-60HT495W open-circuit voltage rises from 43.4V to 46.95V (using βVoc -0.234%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Hanersun Energy HN18N-60HT495W?
Rated at 495W STC, the HN18N-60HT495W carries a 470.1W PTC rating (95% PTC/STC ratio) and 23.46% module efficiency across 2.11 m² (22.7 sq ft).
Is the Hanersun Energy HN18N-60HT495W listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.