JA Solar JAM72S30-530/MR
530 W, 144 half-cell Mono PERC PV Module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
530W / 498.7W
Efficiency
21.03%
Voc / Vmp
49.3V / 41.31V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | JA Solar |
|---|---|
| Model Number (MPN) | JAM72S30-530/MR |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 530 W |
| Real-World Output (PTC) | 498.7 W (94.1% of STC) |
| Module Efficiency | 21.03% (210.3 W/m²) |
| Open-Circuit Voltage (Voc) | 49.3 V |
| Maximum Power Voltage (Vmp) | 41.31 V |
| Short-Circuit Current (Isc) | 13.72 A (NEC 1.25× = 17.15 A) |
| Maximum Power Current (Imp) | 12.83 A |
| Temp. Coeff. Power (γPmax) | -0.33 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.262 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 43.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.52 m² (27.1 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.262%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49.3 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 52.53 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53.82 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 55.11 V | 10 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 56.4 V | 10 | 17 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 12 panels | 6.36 kW | 326 sq ft (30.2 m²) |
| 8 kW | 16 panels | 8.48 kW | 434 sq ft (40.3 m²) |
| 10 kW | 19 panels | 10.07 kW | 515 sq ft (47.9 m²) |
| 12 kW | 23 panels | 12.19 kW | 624 sq ft (58.0 m²) |
Compatible CEC-Listed Inverters for JAM72S30-530/MR
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.38 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This JA Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| JAM72S30-535/MR | 535 W | 503.5 W | 49.45 V | 13.79 A | 21.23% |
| JAM72S30-540/MR | 540 W | 508.3 W | 49.6 V | 13.86 A | 21.43% |
| JAM72S30-545/MR | 545 W | 513.2 W | 49.75 V | 13.93 A | 21.63% |
| JAM72S30-550/MR | 550 W | 518 W | 49.9 V | 14 A | 21.83% |
| JAM72S30-555/MR | 555 W | 522.8 W | 50.05 V | 14.07 A | 22.02% |
Engineering FAQ — JA Solar JAM72S30-530/MR
How many JA Solar JAM72S30-530/MR panels can fit in one 600V string?
At -10°C (14°F) ambient, the JAM72S30-530/MR open-circuit voltage rises from 49.3V to 53.82V (using βVoc -0.262%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the JA Solar JAM72S30-530/MR?
Rated at 530W STC, the JAM72S30-530/MR carries a 498.7W PTC rating (94.1% PTC/STC ratio) and 21.03% module efficiency across 2.52 m² (27.1 sq ft).
Is the JA Solar JAM72S30-530/MR listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.