JA Solar JAM78D30-580/MB
580 W, 156 half-cut cell bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
580W / 543.5W
Efficiency
21.32%
Voc / Vmp
53.11V / 44.35V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | JA Solar |
|---|---|
| Model Number (MPN) | JAM78D30-580/MB |
| Cell Technology | Mono-c-Si (Bifacial) · 156 cells |
| Nameplate Power (Pmax STC) | 580 W |
| Real-World Output (PTC) | 543.5 W (93.7% of STC) |
| Module Efficiency | 21.32% (213.2 W/m²) |
| Open-Circuit Voltage (Voc) | 53.11 V |
| Maximum Power Voltage (Vmp) | 44.35 V |
| Short-Circuit Current (Isc) | 13.84 A (NEC 1.25× = 17.30 A) |
| Maximum Power Current (Imp) | 13.08 A |
| Temp. Coeff. Power (γPmax) | -0.336 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.247 %/°C |
| Temp. Coeff. Current (αIsc) | +0.035 %/°C |
| Nominal Cell Temp (NOCT) | 44.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.72 m² (29.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.247%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 53.11 V | 11 | 18 |
| 0°C / 32°F Freezing / Mild Winter | 56.39 V | 10 | 17 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 57.7 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 59.01 V | 10 | 16 |
| -30°C / -22°F Northern Plains / Mountain | 60.32 V | 9 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 11 panels | 6.38 kW | 322 sq ft (29.9 m²) |
| 8 kW | 14 panels | 8.12 kW | 410 sq ft (38.1 m²) |
| 10 kW | 18 panels | 10.44 kW | 527 sq ft (49.0 m²) |
| 12 kW | 21 panels | 12.18 kW | 615 sq ft (57.1 m²) |
Compatible CEC-Listed Inverters for JAM78D30-580/MB
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ8X-80-E-US | Microinverter | 0.384 kW | 97% | 1:1 micro pairing (1.51 DC/AC ratio) | Verify Pair |
| Fronius Primo 5.0-1 208-240 | String | 5 kW | 96.5% | 3–13 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 3–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This JA Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| JAM78D30-585/MB | 585 W | 548.3 W | 53.2 V | 13.88 A | 21.51% |
| JAM78D30-590/MB | 590 W | 553.2 W | 53.3 V | 13.93 A | 21.69% |
| JAM78D30-595/MB | 595 W | 558 W | 53.4 V | 13.98 A | 21.88% |
| JAM78D30-600/MB | 600 W | 562.8 W | 53.5 V | 14.03 A | 22.06% |
| JAM78D30-605/MB | 605 W | 567.6 W | 53.61 V | 14.08 A | 22.24% |
Engineering FAQ — JA Solar JAM78D30-580/MB
How many JA Solar JAM78D30-580/MB panels can fit in one 600V string?
At -10°C (14°F) ambient, the JAM78D30-580/MB open-circuit voltage rises from 53.11V to 57.7V (using βVoc -0.247%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the JA Solar JAM78D30-580/MB?
Rated at 580W STC, the JAM78D30-580/MB carries a 543.5W PTC rating (93.7% PTC/STC ratio) and 21.32% module efficiency across 2.72 m² (29.3 sq ft).
Is the JA Solar JAM78D30-580/MB listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.