Jiangyin Hareon Power HR-240P-AC/Bb
240 W DC, Polycrystalline ACPV Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
240W / 216.1W
Efficiency
14.79%
Voc / Vmp
37.25V / 29.67V
Max String (600V)
14 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Jiangyin Hareon Power |
|---|---|
| Model Number (MPN) | HR-240P-AC/Bb |
| Cell Technology | Multi-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 240 W |
| Real-World Output (PTC) | 216.1 W (90% of STC) |
| Module Efficiency | 14.79% (147.9 W/m²) |
| Open-Circuit Voltage (Voc) | 37.25 V |
| Maximum Power Voltage (Vmp) | 29.67 V |
| Short-Circuit Current (Isc) | 8.48 A (NEC 1.25× = 10.60 A) |
| Maximum Power Current (Imp) | 8.09 A |
| Temp. Coeff. Power (γPmax) | -0.453 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.349 %/°C |
| Temp. Coeff. Current (αIsc) | +0.057 %/°C |
| Nominal Cell Temp (NOCT) | 45.8 °C |
| Dimensions (L × W) | 1636 × 992 mm (64.4" × 39.1") |
| Surface Area | 1.623 m² (17.5 sq ft) |
| Safety Listing | UL 1741 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.349%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 37.25 V | 16 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 40.5 V | 14 | 24 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 41.8 V | 14 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 43.1 V | 13 | 23 |
| -30°C / -22°F Northern Plains / Mountain | 44.4 V | 13 | 22 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 25 panels | 6.00 kW | 437 sq ft (40.6 m²) |
| 8 kW | 34 panels | 8.16 kW | 594 sq ft (55.2 m²) |
| 10 kW | 42 panels | 10.08 kW | 734 sq ft (68.2 m²) |
| 12 kW | 50 panels | 12.00 kW | 873 sq ft (81.2 m²) |
CEC-Listed US Equivalents to Jiangyin Hareon Power HR-240P-AC/Bb
Looking to build a compliant US residential system with comparable wattage (240W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for HR-240P-AC/Bb
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–14 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-72-2-US | Microinverter | 0.19 kW | 96.5% | 1:1 micro pairing (1.26 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–19 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 7–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 7–11 panels/string at -10°C | Verify Pair |
Engineering FAQ — Jiangyin Hareon Power HR-240P-AC/Bb
How many Jiangyin Hareon Power HR-240P-AC/Bb panels can fit in one 600V string?
At -10°C (14°F) ambient, the HR-240P-AC/Bb open-circuit voltage rises from 37.25V to 41.8V (using βVoc -0.349%/°C), allowing up to 14 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Jiangyin Hareon Power HR-240P-AC/Bb?
Rated at 240W STC, the HR-240P-AC/Bb carries a 216.1W PTC rating (90% PTC/STC ratio) and 14.79% module efficiency across 1.623 m² (17.5 sq ft).
Is the Jiangyin Hareon Power HR-240P-AC/Bb listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1741). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.