Kyocera KD260GX-LFB2 (Legacy Reference)
260W Multi-c-Si Solar Panel (UL 1703 (Legacy Reference)). Registry source: Manufacturer IEC Datasheet (Global Reference) · CEC listing date: · Registry snapshot: .
STC / PTC Power
260W / 232W
Efficiency
15.8%
Voc / Vmp
38.3V / 31V
Max String (600V)
13 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Kyocera |
|---|---|
| Model Number (MPN) | KD260GX-LFB2 (Legacy Reference) |
| Cell Technology | Multi-c-Si · 60 cells |
| Nameplate Power (Pmax STC) | 260 W |
| Real-World Output (PTC) | 232 W (89.2% of STC) |
| Module Efficiency | 15.8% (158 W/m²) |
| Open-Circuit Voltage (Voc) | 38.3 V |
| Maximum Power Voltage (Vmp) | 31 V |
| Short-Circuit Current (Isc) | 9.09 A (NEC 1.25× = 11.36 A) |
| Maximum Power Current (Imp) | 8.39 A |
| Temp. Coeff. Power (γPmax) | -0.45 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.36 %/°C |
| Temp. Coeff. Current (αIsc) | +0.06 %/°C |
| Nominal Cell Temp (NOCT) | 45 °C |
| Dimensions (L × W) | 1662 × 990 mm (65.4" × 39.0") |
| Surface Area | 1.646 m² (17.7 sq ft) |
| Safety Listing | UL 1703 (Legacy Reference) |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.36%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 38.3 V | 15 | 26 |
| 0°C / 32°F Freezing / Mild Winter | 41.75 V | 14 | 23 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 43.13 V | 13 | 23 |
| -20°C / -4°F Northeast / Midwest Winter | 44.5 V | 13 | 22 |
| -30°C / -22°F Northern Plains / Mountain | 45.88 V | 13 | 21 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 24 panels | 6.24 kW | 425 sq ft (39.5 m²) |
| 8 kW | 31 panels | 8.06 kW | 549 sq ft (51.0 m²) |
| 10 kW | 39 panels | 10.14 kW | 691 sq ft (64.2 m²) |
| 12 kW | 47 panels | 12.22 kW | 833 sq ft (77.4 m²) |
CEC-Listed US Equivalents to Kyocera KD260GX-LFB2 (Legacy Reference)
Looking to build a compliant US residential system with comparable wattage (260W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for KD260GX-LFB2 (Legacy Reference)
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–13 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 8–11 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-84-2-US | Microinverter | 0.21 kW | 96.5% | 1:1 micro pairing (1.24 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–18 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 7–11 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 7–11 panels/string at -10°C | Verify Pair |
Engineering FAQ — Kyocera KD260GX-LFB2 (Legacy Reference)
How many Kyocera KD260GX-LFB2 (Legacy Reference) panels can fit in one 600V string?
At -10°C (14°F) ambient, the KD260GX-LFB2 (Legacy Reference) open-circuit voltage rises from 38.3V to 43.13V (using βVoc -0.36%/°C), allowing up to 13 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Kyocera KD260GX-LFB2 (Legacy Reference)?
Rated at 260W STC, the KD260GX-LFB2 (Legacy Reference) carries a 232W PTC rating (89.2% PTC/STC ratio) and 15.8% module efficiency across 1.646 m² (17.7 sq ft).
Is the Kyocera KD260GX-LFB2 (Legacy Reference) listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1703 (Legacy Reference)). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.