Magnus green solar MGS-445W-M54HN-M10
445 W, 144 half-cut cell monocrystalline module, black backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
445W / 415.9W
Efficiency
20.14%
Voc / Vmp
50.6V / 42V
Max String (600V)
10 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Magnus green solar |
|---|---|
| Model Number (MPN) | MGS-445W-M54HN-M10 |
| Cell Technology | Mono-c-Si · 144 cells |
| Nameplate Power (Pmax STC) | 445 W |
| Real-World Output (PTC) | 415.9 W (93.5% of STC) |
| Module Efficiency | 20.14% (201.4 W/m²) |
| Open-Circuit Voltage (Voc) | 50.6 V |
| Maximum Power Voltage (Vmp) | 42 V |
| Short-Circuit Current (Isc) | 11.37 A (NEC 1.25× = 14.21 A) |
| Maximum Power Current (Imp) | 10.61 A |
| Temp. Coeff. Power (γPmax) | -0.359 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.309 %/°C |
| Temp. Coeff. Current (αIsc) | +0.059 %/°C |
| Nominal Cell Temp (NOCT) | 43.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.21 m² (23.8 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.309%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 50.6 V | 11 | 19 |
| 0°C / 32°F Freezing / Mild Winter | 54.51 V | 11 | 18 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 56.07 V | 10 | 17 |
| -20°C / -4°F Northeast / Midwest Winter | 57.64 V | 10 | 17 |
| -30°C / -22°F Northern Plains / Mountain | 59.2 V | 10 | 16 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.23 kW | 333 sq ft (30.9 m²) |
| 8 kW | 18 panels | 8.01 kW | 428 sq ft (39.8 m²) |
| 10 kW | 23 panels | 10.23 kW | 547 sq ft (50.8 m²) |
| 12 kW | 27 panels | 12.02 kW | 642 sq ft (59.7 m²) |
Compatible CEC-Listed Inverters for MGS-445W-M54HN-M10
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–10 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–8 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–14 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–8 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–8 panels/string at -10°C | Verify Pair |
Other Power Classes in This Magnus green solar Series (4 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| MGS-425W-M54HN-M10 | 425 W | 396.8 W | 50 V | 11.29 A | 19.23% |
| MGS-430W-M54HN-M10 | 430 W | 401.6 W | 50.2 V | 11.3 A | 19.46% |
| MGS-440W-M54HN-M10 | 440 W | 411.1 W | 50.5 V | 11.34 A | 19.91% |
Engineering FAQ — Magnus green solar MGS-445W-M54HN-M10
How many Magnus green solar MGS-445W-M54HN-M10 panels can fit in one 600V string?
At -10°C (14°F) ambient, the MGS-445W-M54HN-M10 open-circuit voltage rises from 50.6V to 56.07V (using βVoc -0.309%/°C), allowing up to 10 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Magnus green solar MGS-445W-M54HN-M10?
Rated at 445W STC, the MGS-445W-M54HN-M10 carries a 415.9W PTC rating (93.5% PTC/STC ratio) and 20.14% module efficiency across 2.21 m² (23.8 sq ft).
Is the Magnus green solar MGS-445W-M54HN-M10 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.