Merlin Solar Technologies RFP-F036W185L
185 W, 36 cell monocrystalline PERC module, white backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
185W / 167.9W
Efficiency
16.97%
Voc / Vmp
24.5V / 20.9V
Max String (600V)
22 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Merlin Solar Technologies |
|---|---|
| Model Number (MPN) | RFP-F036W185L |
| Cell Technology | Mono-c-Si · 36 cells |
| Nameplate Power (Pmax STC) | 185 W |
| Real-World Output (PTC) | 167.9 W (90.8% of STC) |
| Module Efficiency | 16.97% (169.7 W/m²) |
| Open-Circuit Voltage (Voc) | 24.5 V |
| Maximum Power Voltage (Vmp) | 20.9 V |
| Short-Circuit Current (Isc) | 9.25 A (NEC 1.25× = 11.56 A) |
| Maximum Power Current (Imp) | 8.87 A |
| Temp. Coeff. Power (γPmax) | -0.317 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.262 %/°C |
| Temp. Coeff. Current (αIsc) | +0.053 %/°C |
| Nominal Cell Temp (NOCT) | 53.7 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.09 m² (11.7 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.262%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 24.5 V | 24 | 40 |
| 0°C / 32°F Freezing / Mild Winter | 26.1 V | 22 | 38 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 26.75 V | 22 | 37 |
| -20°C / -4°F Northeast / Midwest Winter | 27.39 V | 21 | 36 |
| -30°C / -22°F Northern Plains / Mountain | 28.03 V | 21 | 35 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 33 panels | 6.11 kW | 387 sq ft (36.0 m²) |
| 8 kW | 44 panels | 8.14 kW | 516 sq ft (48.0 m²) |
| 10 kW | 55 panels | 10.18 kW | 645 sq ft (60.0 m²) |
| 12 kW | 65 panels | 12.03 kW | 763 sq ft (70.9 m²) |
CEC-Listed US Equivalents to Merlin Solar Technologies RFP-F036W185L
Looking to build a compliant US residential system with comparable wattage (185W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for RFP-F036W185L
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–22 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 12–17 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-72-2-US | Microinverter | 0.19 kW | 96.5% | 1:1 micro pairing (0.97 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 6–29 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 10–18 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 10–18 panels/string at -10°C | Verify Pair |
Engineering FAQ — Merlin Solar Technologies RFP-F036W185L
How many Merlin Solar Technologies RFP-F036W185L panels can fit in one 600V string?
At -10°C (14°F) ambient, the RFP-F036W185L open-circuit voltage rises from 24.5V to 26.75V (using βVoc -0.262%/°C), allowing up to 22 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Merlin Solar Technologies RFP-F036W185L?
Rated at 185W STC, the RFP-F036W185L carries a 167.9W PTC rating (90.8% PTC/STC ratio) and 16.97% module efficiency across 1.09 m² (11.7 sq ft).
Is the Merlin Solar Technologies RFP-F036W185L listed in the CEC registry for US residential designs?
No — this model is categorized as CEC-Listed · Availability Not Checked (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.