Panasonic EVPV410HK
410 W, 132 half cut cell monocrystalline module, black backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
410W / 390.8W
Efficiency
22.91%
Voc / Vmp
49V / 42.7V
Max String (600V)
11 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Panasonic |
|---|---|
| Model Number (MPN) | EVPV410HK |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 410 W |
| Real-World Output (PTC) | 390.8 W (95.3% of STC) |
| Module Efficiency | 22.91% (229.1 W/m²) |
| Open-Circuit Voltage (Voc) | 49 V |
| Maximum Power Voltage (Vmp) | 42.7 V |
| Short-Circuit Current (Isc) | 10.35 A (NEC 1.25× = 12.94 A) |
| Maximum Power Current (Imp) | 9.61 A |
| Temp. Coeff. Power (γPmax) | -0.256 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.233 %/°C |
| Temp. Coeff. Current (αIsc) | +0.034 %/°C |
| Nominal Cell Temp (NOCT) | 45 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.79 m² (19.3 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.233%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 49 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 51.85 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 53 V | 11 | 18 |
| -20°C / -4°F Northeast / Midwest Winter | 54.14 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 55.28 V | 10 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 15 panels | 6.15 kW | 289 sq ft (26.9 m²) |
| 8 kW | 20 panels | 8.20 kW | 385 sq ft (35.8 m²) |
| 10 kW | 25 panels | 10.25 kW | 482 sq ft (44.8 m²) |
| 12 kW | 30 panels | 12.30 kW | 578 sq ft (53.7 m²) |
Compatible CEC-Listed Inverters for EVPV410HK
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 6–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–15 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Panasonic Series (3 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| EVPV390HK | 390 W | 371.3 W | 48.6 V | 10.19 A | 21.79% |
| EVPV400HK | 400 W | 381.1 W | 48.8 V | 10.25 A | 22.35% |
Engineering FAQ — Panasonic EVPV410HK
How many Panasonic EVPV410HK panels can fit in one 600V string?
At -10°C (14°F) ambient, the EVPV410HK open-circuit voltage rises from 49V to 53V (using βVoc -0.233%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Panasonic EVPV410HK?
Rated at 410W STC, the EVPV410HK carries a 390.8W PTC rating (95.3% PTC/STC ratio) and 22.91% module efficiency across 1.79 m² (19.3 sq ft).
Is the Panasonic EVPV410HK listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 61730). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.