Perlight Solar PLM-290P-72
290 W Polycrystalline Module. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
290W / 258.4W
Efficiency
14.87%
Voc / Vmp
45.14V / 35.27V
Max String (600V)
11 @ −10°C
System Design Actions
Reference Datasheet Only: This module is not marked for new US residential kit builds. Compare CEC-listed US equivalents below.
View CEC-Listed Equivalents →Run String Voltage Check →
Electrical & Thermal Specifications (STC)
| Manufacturer | Perlight Solar |
|---|---|
| Model Number (MPN) | PLM-290P-72 |
| Cell Technology | Multi-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 290 W |
| Real-World Output (PTC) | 258.4 W (89.1% of STC) |
| Module Efficiency | 14.87% (148.7 W/m²) |
| Open-Circuit Voltage (Voc) | 45.14 V |
| Maximum Power Voltage (Vmp) | 35.27 V |
| Short-Circuit Current (Isc) | 8.69 A (NEC 1.25× = 10.86 A) |
| Maximum Power Current (Imp) | 8.23 A |
| Temp. Coeff. Power (γPmax) | -0.44 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.32 %/°C |
| Temp. Coeff. Current (αIsc) | +0.05 %/°C |
| Nominal Cell Temp (NOCT) | 48.5 °C |
| Dimensions (L × W) | 1966 × 992 mm (77.4" × 39.1") |
| Surface Area | 1.95 m² (21.0 sq ft) |
| Safety Listing | UL 1741 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.32%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 45.14 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 48.75 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 50.2 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 51.64 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 53.08 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 21 panels | 6.09 kW | 441 sq ft (40.9 m²) |
| 8 kW | 28 panels | 8.12 kW | 588 sq ft (54.6 m²) |
| 10 kW | 35 panels | 10.15 kW | 735 sq ft (68.3 m²) |
| 12 kW | 42 panels | 12.18 kW | 882 sq ft (81.9 m²) |
CEC-Listed US Equivalents to Perlight Solar PLM-290P-72
Looking to build a compliant US residential system with comparable wattage (290W) and efficiency? These CEC-listed UL 61730 models can be added straight to your kit:
Compatible CEC-Listed Inverters for PLM-290P-72
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PD-84-2-US | Microinverter | 0.21 kW | 96.5% | 1:1 micro pairing (1.38 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–15 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This Perlight Solar Series (2 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| PLM-270P-72 | 270 W | 240.1 W | 44.76 V | 8.58 A | 13.84% |
Engineering FAQ — Perlight Solar PLM-290P-72
How many Perlight Solar PLM-290P-72 panels can fit in one 600V string?
At -10°C (14°F) ambient, the PLM-290P-72 open-circuit voltage rises from 45.14V to 50.2V (using βVoc -0.32%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Perlight Solar PLM-290P-72?
Rated at 290W STC, the PLM-290P-72 carries a 258.4W PTC rating (89.1% PTC/STC ratio) and 14.87% module efficiency across 1.95 m² (21.0 sq ft).
Is the Perlight Solar PLM-290P-72 listed in the CEC registry for US residential designs?
No — this model is categorized as Legacy / Replacement Reference (UL 1741). Homeowners in the US can compare active CEC-listed equivalents directly on this datasheet page.