PT. Deltamas Solusindo SQF380M-72
380 W, 72 cell monocrystalline module, white backsheet, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
380W / 356.8W
Efficiency
18.91%
Voc / Vmp
48.16V / 39.7V
Max String (600V)
11 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | PT. Deltamas Solusindo |
|---|---|
| Model Number (MPN) | SQF380M-72 |
| Cell Technology | Mono-c-Si · 72 cells |
| Nameplate Power (Pmax STC) | 380 W |
| Real-World Output (PTC) | 356.8 W (93.9% of STC) |
| Module Efficiency | 18.91% (189.1 W/m²) |
| Open-Circuit Voltage (Voc) | 48.16 V |
| Maximum Power Voltage (Vmp) | 39.7 V |
| Short-Circuit Current (Isc) | 10.16 A (NEC 1.25× = 12.70 A) |
| Maximum Power Current (Imp) | 9.59 A |
| Temp. Coeff. Power (γPmax) | -0.311 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.232 %/°C |
| Temp. Coeff. Current (αIsc) | +0.025 %/°C |
| Nominal Cell Temp (NOCT) | 44.9 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 2.01 m² (21.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.232%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 48.16 V | 12 | 20 |
| 0°C / 32°F Freezing / Mild Winter | 50.95 V | 11 | 19 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 52.07 V | 11 | 19 |
| -20°C / -4°F Northeast / Midwest Winter | 53.19 V | 11 | 18 |
| -30°C / -22°F Northern Plains / Mountain | 54.31 V | 11 | 18 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.08 kW | 346 sq ft (32.2 m²) |
| 8 kW | 22 panels | 8.36 kW | 476 sq ft (44.2 m²) |
| 10 kW | 27 panels | 10.26 kW | 584 sq ft (54.3 m²) |
| 12 kW | 32 panels | 12.16 kW | 692 sq ft (64.3 m²) |
Compatible CEC-Listed Inverters for SQF380M-72
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–11 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.41 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 3–15 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 5–9 panels/string at -10°C | Verify Pair |
Other Power Classes in This PT. Deltamas Solusindo Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SQF385M-72 | 385 W | 361.6 W | 48.16 V | 10.16 A | 19.15% |
| SQF390M-72 | 390 W | 366.4 W | 48.16 V | 10.16 A | 19.4% |
| SQF395M-72 | 395 W | 371.2 W | 48.88 V | 10.24 A | 19.65% |
| SQF400M-72 | 400 W | 376 W | 49.32 V | 10.37 A | 19.9% |
Engineering FAQ — PT. Deltamas Solusindo SQF380M-72
How many PT. Deltamas Solusindo SQF380M-72 panels can fit in one 600V string?
At -10°C (14°F) ambient, the SQF380M-72 open-circuit voltage rises from 48.16V to 52.07V (using βVoc -0.232%/°C), allowing up to 11 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the PT. Deltamas Solusindo SQF380M-72?
Rated at 380W STC, the SQF380M-72 carries a 356.8W PTC rating (93.9% PTC/STC ratio) and 18.91% module efficiency across 2.01 m² (21.6 sq ft).
Is the PT. Deltamas Solusindo SQF380M-72 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.