Qcells (Hanwha) Q.PEAK DUO BLK ML-G10.D+ 395
395 W, 132 half-cut cell monocrystalline module, black backsheet, 1000V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
395W / 371.4W
Efficiency
20.68%
Voc / Vmp
45.27V / 36.88V
Max String (600V)
12 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | Qcells (Hanwha) |
|---|---|
| Model Number (MPN) | Q.PEAK DUO BLK ML-G10.D+ 395 |
| Cell Technology | Mono-c-Si · 132 cells |
| Nameplate Power (Pmax STC) | 395 W |
| Real-World Output (PTC) | 371.4 W (94% of STC) |
| Module Efficiency | 20.68% (206.8 W/m²) |
| Open-Circuit Voltage (Voc) | 45.27 V |
| Maximum Power Voltage (Vmp) | 36.88 V |
| Short-Circuit Current (Isc) | 11.1 A (NEC 1.25× = 13.88 A) |
| Maximum Power Current (Imp) | 10.71 A |
| Temp. Coeff. Power (γPmax) | -0.337 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.261 %/°C |
| Temp. Coeff. Current (αIsc) | +0.043 %/°C |
| Nominal Cell Temp (NOCT) | 43.6 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6")(Class Estimate — Verify Datasheet) |
| Surface Area | 1.91 m² (20.6 sq ft) (Est.) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.261%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 45.27 V | 13 | 22 |
| 0°C / 32°F Freezing / Mild Winter | 48.22 V | 12 | 20 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 49.41 V | 12 | 20 |
| -20°C / -4°F Northeast / Midwest Winter | 50.59 V | 11 | 19 |
| -30°C / -22°F Northern Plains / Mountain | 51.77 V | 11 | 19 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 16 panels | 6.32 kW | 329 sq ft (30.6 m²) |
| 8 kW | 21 panels | 8.29 kW | 432 sq ft (40.1 m²) |
| 10 kW | 26 panels | 10.27 kW | 535 sq ft (49.7 m²) |
| 12 kW | 31 panels | 12.24 kW | 637 sq ft (59.2 m²) |
Compatible CEC-Listed Inverters for Q.PEAK DUO BLK ML-G10.D+ 395
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–12 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 7–9 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ6PLUS-ACB-LL | Microinverter | 0.27 kW | 95.5% | 1:1 micro pairing (1.46 DC/AC ratio) | Verify Pair |
| Fronius Primo 3.8-1 208-240 | String | 3.8 kW | 95.5% | 4–16 panels/string at -10°C | Verify Pair |
| GoodWe GEP5.0-1-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-MS-US30 | String | 4.968 kW | 96.5% | 6–10 panels/string at -10°C | Verify Pair |
Other Power Classes in This Qcells (Hanwha) Series (5 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| Q.PEAK DUO BLK ML-G10.D+ 400 | 400 W | 376.2 W | 45.3 V | 11.14 A | 20.94% |
| Q.PEAK DUO BLK ML-G10.D+ 405 | 405 W | 381 W | 45.34 V | 11.17 A | 21.2% |
| Q.PEAK DUO BLK ML-G10.D+ 410 | 410 W | 385.9 W | 45.37 V | 11.2 A | 21.47% |
| Q.PEAK DUO BLK ML-G10.D+ 415 | 415 W | 390.7 W | 45.41 V | 11.23 A | 21.73% |
Engineering FAQ — Qcells (Hanwha) Q.PEAK DUO BLK ML-G10.D+ 395
How many Qcells (Hanwha) Q.PEAK DUO BLK ML-G10.D+ 395 panels can fit in one 600V string?
At -10°C (14°F) ambient, the Q.PEAK DUO BLK ML-G10.D+ 395 open-circuit voltage rises from 45.27V to 49.41V (using βVoc -0.261%/°C), allowing up to 12 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the Qcells (Hanwha) Q.PEAK DUO BLK ML-G10.D+ 395?
Rated at 395W STC, the Q.PEAK DUO BLK ML-G10.D+ 395 carries a 371.4W PTC rating (94% PTC/STC ratio) and 20.68% module efficiency across 1.91 m² (20.6 sq ft).
Is the Qcells (Hanwha) Q.PEAK DUO BLK ML-G10.D+ 395 listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.